Functions of the room- and radio components
S. 73
11.2.5
Connection test heatapp! drive
Fig.: 51: Connection test heatapp! drive
1.
Press the middle key for at least 3 seconds until "M" is output to the display.
2.
Then press the left key until "LI" is displayed and confirm with the central key. This approach triggers a device
connection test.
3.
Press key (1) to test the connection.
"LI" is hidden as soon as the connection has been made. If no wireless connection to the
heatapp! gateway
is made, the symbols
"Wireless connection" and "Alarm" flash in the display.
11.2.6
Matching to the radiator / room conditions
The
heatapp! drive
has an option where it can be matched to the radiator or room conditions. In this way you can compensate
for over or under-dimensioned radiators.
The default setting is P2.
1.
Press the learn key on the
heatapp! drive
until an "M" is output to the display.
2.
Repeatedly press "Down" until "Pb" appears in the display. Press the learn key to confirm the selection.
3.
Select the desired adjustment with the up or down key according to the following table.
P1
For over-dimensioned radiators.
P2
Factory setting
for "normally" dimensioned radiators.
P3
For under-dimensioned radiators.