Functions of the room- and radio components
S. 69
11
Functions of the room- and radio components
11.1
heatapp! sense-wire
Fig.: 45:
heatapp! sense
-wire
heatapp! sense-wire
is a wired temperature sensor for measuring the room temperature in
heatapp! base/baseT2B.
The device
is mounted on the wall and connected to the E1 input of the
heatapp! base/heatapp! base T2B
.
For example,
heatapp! sense-wire
replaces a room station.
heatapp!
sense-wire is automatically detected by
heatapp!
base. Registration is not necessary.
For example,
heatapp!
sense-wire is used in a control system according to the reference room principle.
heatapp!
base
determines the heat requirement based on the difference between the setpoint and current temperature.
11.1.1
heatapp! sense- wire installation
Select a suitable installation location. Ensure that no pipes or cables are routed in the wall beneath the mounting location
that could be damaged by the installation.
Ensure that a connection to the
heatapp! base/T2B
can be established at the installation location.
Route the connecting cable to the sensor through the opening on the casing bottom and screw the casing bottom to the
wall through the fastening holes.
Connect the cable, which is polarity-insensitive, to the connection terminals on the
heatapp! sense-wire
and the
connection terminals E1 and GND of the
heatapp! base/T2B
.
11.1.2
Closing the casing
Place the casing top on top of the casing bottom.
11.1.3
heatapp! sense- wire startup
In the setup wizard, select the heatapp! base/T2B with the energy generator/single room heat regulation “off”, to activate the
input E1 of the heatapp! base/T2B as the room sensor ((E1:EF for sensor input). Activate the heatapp! sense-wire for one of the
available room groups.
Follow the setup wizard, until heatapp! base/T2B is completely set up.
Содержание T2B
Страница 21: ...Installation and initial operation S 21 Fig 8 Connection variant wall base MS K Fig 9 Connection variant THETA...
Страница 66: ...Control S 66 10 2 6 3 Network Fig 44 Network configuration gateway...
Страница 121: ...Technische Daten S 121 18 3 Drilling template heatapp base heatapp base T2B Fig 76 Drilling template heatapp base...