Control
S. 41
„Holiday“ scene
The "Holiday" scene is used to set the holiday duration in days. To do so, the holiday duration is entered from the current day
using the slide control in days. Activation of the holiday function ensures that the temperature does not fall below the minimum
temperature (frost protection) of the rooms.
In contrast to the Go scene (setback temperature), in the Holiday scene, the temperature is set to the frost protection
temperature. The active holiday rooms can no longer be controlled using the thermostat rotary control.
DHW heating is deactivated for the scene runtime (only with DHW connection via the bus system Open Therm, T2B). However a
set Legionella protection scheme remains active.
The scene runtime can be set in days up to a maximum of 30 days
„Standby“ scene
Using the standby function, the selected rooms are switched off in a frost-protected manner. In contrast to the holiday scene, the
standby function has no time limit.
The setting for switching off hot water generation should be considered here. In the Expert menu of the
heatapp!
base a
selection can be made between room switching off and operation mode switching off for hot water generation.
If for hot water generation switching off is set to “Room”, then hot water generation is also deactivated if all rooms are in
standby mode. If one room remains active, hot water generation takes places according to the timer programs.
If hot water generation switching off is set to “operation mode”, then, even in standby mode, it remains set to automatic
operation and control takes place according to the timer programs, even if all the rooms are in standby. The standby function
corresponds to “Summer” operation mode.
10.2.2
The "Settings" menu
The "
Settings
" operating level is used for access to advanced functions.
The menu items "
My profile
", "
Design
", "
Cycle times
" and "
Live View
" are available to all users.
In addition the additional menu items "
Rooms
", "
Users
", "
Devices
", "
Scenes
", "
System
" and "
Gateway
" are available to Expert and
Owner users.
„Settings“ menu
Tap the gearwheel symbol to access the settings level. The individual menu symbols are shown on the left.
On the right you can edit the individual menu items.
Содержание T2B
Страница 21: ...Installation and initial operation S 21 Fig 8 Connection variant wall base MS K Fig 9 Connection variant THETA...
Страница 66: ...Control S 66 10 2 6 3 Network Fig 44 Network configuration gateway...
Страница 121: ...Technische Daten S 121 18 3 Drilling template heatapp base heatapp base T2B Fig 76 Drilling template heatapp base...