Heat & Glo  •   6000CMOD-IPI, 8000CMOD-IPI  •  2241-900 Rev. K  •  4/14

8

H. Requirements for the Commonwealth of 

Massachusetts

For all side wall horizontally vented gas fueled equipment 
installed in every dwelling, building or structure used in 
whole or in part for residential purposes, including those 
owned or operated by the Commonwealth and where the 
side wall exhaust vent termination is less than seven (7) 
feet above 

fi

 nished grade in the area of the venting, in-

cluding but not limited to decks and porches, the following 
requirements shall be satis

fi

 ed:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented 
gas fueled equipment, the installing plumber or gas 

fi

 tter 

shall observe that a hard wired carbon monoxide detector 
with an alarm and battery back-up is installed on the 

fl

 oor 

level where the gas equipment is to be installed. In addi-
tion, the installing plumber or gas 

fi

 tter shall observe that 

a battery operated or hard wired carbon monoxide detec-
tor with an alarm is installed on each additional level of 
the dwelling, building or structure served by the side wall 
horizontal vented gas fueled equipment. It shall be the 
responsibility of the property owner to secure the services 
of quali

fi

 ed licensed professionals for the installation of 

hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic, 
the hard wired carbon monoxide detector with alarm and 
battery back-up may be installed on the next adjacent 

fl

 oor level.

In the event that the requirements of this subdivision can 
not be met at the time of completion of installation, the 
owner shall have a period of thirty (30) days to comply 
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon 
monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor-
dance with the above provisions shall comply with NFPA 
720 and be ANSI/UL 2034 listed and IAS certi

fi

 ed. 

Signage

A metal or plastic identi

fi

 cation plate shall be permanent-

ly mounted to the exterior of the building at a minimum 
height of eight (8) feet above grade directly in line with the 
exhaust vent terminal for the horizontally vented gas fu-
eled heating appliance or equipment. The sign shall read, 
in print size no less than one-half (1/2) in. in size, 

“GAS 

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the 
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed 
in accordance with the provisions of 248 CMR 5.08(2)(a)1 
through 4. 

Exemptions

The following equipment is exempt from 248 CMR 
5.08(2)(a)1 through 4: 
•  The equipment listed in Chapter 10 entitled “Equipment 

Not Required To Be Vented” in the most current edition 
of NFPA 54 as adopted by the Board; and 

•  Product Approved side wall horizontally vented gas fu-

eled equipment installed in a room or structure separate 
from the dwelling, building or structure used in whole or 
in part for residential purposes. 

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall 
horizontally vented gas equipment provides a venting 
system design or venting system components with the 
equipment, the instructions provided by the manufacturer 
for installation of the equipment and the venting system 
shall include:
•  Detailed instructions for the installation of the venting 

system design or the venting system components; and

•  A complete parts list for the venting system design or 

venting system. 

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall 
horizontally vented gas fueled equipment does not pro-
vide the parts for venting the 

fl

 ue gases, but identi

fi

 es 

“special venting systems”, the following requirements 
shall be satis

fi

 ed by the manufacturer:

• The referenced “special venting system” instructions 

shall be included with the appliance or equipment in-
stallation instructions; and 

• The “special venting systems” shall be Product Ap-

proved by the Board, and the instructions for that sys-
tem shall include a parts list and detailed installation 
instructions. 

A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting 
instructions, and/or all venting design instructions shall 
remain with the appliance or equipment at the completion 
of the installation. 

See Gas Connection section for additional Common-
wealth of Massachusetts requirements.

Note: 

The following requirements reference various 

Massachusetts and national codes not contained in this 
document.

Содержание 6000CMOD-IPI

Страница 1: ...ssional Leave this manual with party responsible for use and operation DO NOT DISCARD Important operating and maintenance instructions included Read understand and follow these instructions for safe i...

Страница 2: ...r Type of Gas Model Number Not Not for for use use with with solid solid fuel fuel Ne Ne doit doit pas pas entre entre utilise utilise avec avec un un combustible combustible solide solide This This a...

Страница 3: ...18 B Design and Installation Considerations 19 C Tools and Supplies Needed 19 D Inspect Appliance and Components 19 5 Framing and Clearances A Selecting Appliance Location 20 B Constructing the Applia...

Страница 4: ...ve Fixed Glass Assembly 52 B Remove the Shipping Materials 52 C Clean the Appliance 52 D Accessories 52 E Glass Panel Installation 52 F Media Placement 53 G Fixed Glass Assembly 55 H Install Trim and...

Страница 5: ...l purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dea...

Страница 6: ...SPECIFIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exteri...

Страница 7: ...Combustible Materials Specification Material which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination t...

Страница 8: ...eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas ins...

Страница 9: ...hot viewing glass is provided with this appliance and shall be installed DO NOT operate the appliance with the barrier removed If the barrier becomes damaged the barrier shall be replaced with the ma...

Страница 10: ...y cause fireplace to overheat This fireplace has been supplied with an integral barrier to prevent direct contact with the fixed glass panel DO NOT operate the fireplace with the barrier removed Conta...

Страница 11: ...an optional wired wall switch and or the wireless remote RC300 2 If using a wired wall switch with the module in REMOTE mode the flame output can be adjusted with the HI LO selector switch on the mod...

Страница 12: ...DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE CONTROL VAL...

Страница 13: ...lease an odor for the first several hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Odor may also be released from finishing materials and...

Страница 14: ...Control Frequency Seasonally By Homeowner Tools needed Replacement batteries and remote con trol instructions Locate remote control transmitter and receiver Verify operation of remote Refer to remote...

Страница 15: ...heet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed...

Страница 16: ...RETAINERS Figure 3 5 Burner Assembly Removal 4 Remove the base pan by removing the screws circled in Figure 3 4 5 Remove the burner assembly by removing the two screws as shown in Figure 3 5 To disen...

Страница 17: ...00 Rev K 4 14 Figure 3 6 Valve Assembly Removal Appearance of valve components may vary 8000CMOD IPI NG 8000CMOD IPI LP Figure 3 8 Valve Assembly Removal 6000CMOD IPI NG 6000CMOD IPI LP Figure 3 7 Val...

Страница 18: ...ION 10 I VENT PIPE PENETRATES ROOF PREFERABLY WITHOUT AFFECTING ROOF RAFTERS SECTION 8 C FRAMING HEADED OFF IN CEILING JOISTS SECTION 8 C GAS LINE SECTION 11 MANTEL AND MANTEL LEG SECTION 5 D SURROUND...

Страница 19: ...losion Damaged parts could impair safe operation DO NOT install damaged in complete or substitute components Keep appliance dry C Tools and Supplies Needed Before beginning the installation be sure th...

Страница 20: ...t of traffic and away from furniture and draperies NOTICE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation...

Страница 21: ...epth DO NOT install directly on carpeting vinyl tile or any combustible material other than wood WARNING Risk of Fire Maintain specified air space clearances to appliance and vent pipe Insulation and...

Страница 22: ...6 17 18 19 32 TO CEILING 9 10 11 12 8 7 6 5 4 3 25 18 A B INTERIOR WALL TOP VIEW MANTEL LEG OR WALL PROJECTIONS FIREPLACE OPENING Note All measurements in inches If A minimum is ____ then B maximum is...

Страница 23: ...CHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 6 6 Termination Locations Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or ot...

Страница 24: ...X V H A V V H Electrical Service V K V K V L C V N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 42 inches vinyl soffit and overhang P 8 ft QMIN RMA...

Страница 25: ...n A length of straight pipe is allowed between two 45 elbows see Figure 7 1 Figure 7 1 7 7 Vent Information and Diagrams B Vent Table Key The abbreviations listed in this vent table key are used in th...

Страница 26: ...ng first elbow WARNING WARNING E Vent Diagrams Note The 6000 8000 series fireplaces can adapt to SLP series vent pipe if desired When venting off the top of the unit use a DVP 2SL adapter and a minimu...

Страница 27: ...mm 2 ft 610 mm 1 ft 305 mm 4 ft 1 2 m 1 1 2 ft 457 mm 11 ft 3 4 m 2 ft 610 mm 17 ft 5 2 m 2 1 2 ft 762 mm 20 ft 6 1 m V1 H1 H2 40 ft 12 2 m Maximum H1 H2 20 ft 6 1 m Maximum V1 1 ft 305 mm Minimum 800...

Страница 28: ...m 6 in 152 mm 3 ft 914 mm 6 in 152 mm 2 ft 610 mm 1 ft 305 mm 6 ft 1 8 m 1 ft 305 mm 6 ft 1 8 m 2 ft 610 mm 11 ft 3 4 m 2 ft 610 mm 10 ft 3 1 m 3 ft 914 mm 16 ft 4 9 m 3 ft 914 mm 14 ft 4 3 m H1 H2 20...

Страница 29: ...ation off the top of the appli ance the flue restrictor should be used See Figure 7 9 V1 V1 40 ft Max 12 4 m V1 3 ft Min 914 mm Figure 7 8 Flue Restrictor 2 Break the flue restrictor into two pieces D...

Страница 30: ...1 2 3 4 5 SETTING 1 2 3 4 5 Vertical TOP VENT NG LP 4 ft 1 1 No Restrictor 8 ft 2 2 1 2 15 ft 3 3 3 2 20 ft 3 3 3 3 25 ft 3 3 3 3 30 ft 3 4 3 4 35 ft 3 4 3 4 40 ft 3 4 4 4 V1 H1 Maximum V2 V1 V2 Min...

Страница 31: ...HORIZONTALLY H1 H2 V1 V2 V1 H1 H2 V2 V1 V2 Minimum H1 H2 Maximum Elbow only 1 ft 305 mm 1 ft 305 mm 6 in 152 mm 2 ft 610 mm 2 ft 610 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 4 ft...

Страница 32: ...only on interior walls If your local inspector requires a wall shield firestop on both sides then both wall shield firestops must have a heat shield refer to Section 16 B attached to them See Section...

Страница 33: ...t Insulation must be kept back from the pipe to prevent overheating Figure 8 3 Installing Ceiling Firestop Figure 8 4 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTA...

Страница 34: ...he fireplace and discard it see Figure 8 5 Center the duct collar around the exposed hole and attach it to the fireplace with 3 screws Note Do this BEFORE final positioning of fireplace Determine the...

Страница 35: ...Figure 9 2 2 Locate the fiberglass gasket in the manual bag Attach the gasket to the outer wrap using two self tapping screws This creates a seal between the first vent component and the outer firepla...

Страница 36: ...secure the appliance see Figure 9 7 Nailing tabs are provided to secure the appliance to the framing members Bend out nailing tabs on each side Place the appliance into position Keep nailing tabs flus...

Страница 37: ...OT penetrate inner pipe For 90 and 45 elbows that are changing the vent direction from horizontal to vertical one screw minimum should be put in the outer flue at the horizontal elbow joint to prevent...

Страница 38: ...outer pipes need to be sealed All unit collar pipe slip section elbow and cap outer flues shall be sealed in this manner unless otherwise stated Figure 10 5 Adding Venting Components WARNING Risk of F...

Страница 39: ...very 8 ft 2 44 m after the maximum allowed 25 ft 7 62 m of unsupported rise Vertical runs originating off the rear of the appliance or after any elbow must be supported every 8 ft 2 44 m Horizontal ru...

Страница 40: ...athedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 1 8 in 3 mm larger than the support bo...

Страница 41: ...ROM ROOF TO LOWEST DISCHARGE OPENING Figure 10 15 Figure 10 15 CAULK NOTICE Failure to properly caulk the roof flashing and pipe seams may permit entry of water Caulk the gap between the roof flashing...

Страница 42: ...s does not allow the required 1 1 2 in 38 mm heat shield overlap when installed an extended heat shield must be used If the wall thickness is less than 4 in 102 mm DVP or 4 3 8 in 111 mm SLP the heat...

Страница 43: ...dge of the cap base Flash and seal as appropriate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current A...

Страница 44: ...solution DO NOT use open flame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WA...

Страница 45: ...iance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switched circuit Incorrect wiring will override IPI safety lockout Refer to Figure 12 1 IPI Wiring Diagr...

Страница 46: ...n Box Detail NOTICE DO NOT wire 110 120 VAC to wall switch Red Switch Switch Box Red Black Black Green Green White Power Supply Wires White Red Black Green White Minimum 14 3 AWG with Ground Junction...

Страница 47: ...ntels Combustible Mantel Legs or Wall Projections MEASUREMENTS FROM TOP EDGE OF THE OPENING 5 10 11 12 2 1 2 13 14 15 16 17 18 19 32 TO CEILING 9 10 11 12 8 7 6 5 4 3 25 18 A B INTERIOR WALL TOP VIEW...

Страница 48: ...d Sealing Joints All joints between the finished wall sheathing and the ap pliance must be sealed with non combustible materials Sealants such as caulk or mastic used to seal the gap between the wall...

Страница 49: ...NOTE THE APPLIANCE MUST BE ELEVATED A MINIMUM OF 1 INCH IN ORDER TO USE THE CMOD DOOR FLOOR ELEVATED HEARTH CMOD DOOR Figure 13 7 Appliance Installed Off the Floor Folio Door Application If the appli...

Страница 50: ...TERIAL THICKNESS SEE FIGURE CMOD 8 BK CMOD 8 GY Overlap 1 inch thick or less 13 8 Inside 1 4 inches maximum 13 9 CMOD 6 BK CMOD 6 GY Overlap 1 inch thick or less 13 8 Inside 1 4 inches maximum 13 9 FO...

Страница 51: ...IBLE FINISHING MATERIAL Figure 13 9 Finishing Material Thickness Greater Than One Inch 8000 Models 6000 Models Inches Millimeters Inches Millimeters A 48 13 16 1240 41 13 16 1062 B 38 3 8 975 36 3 8 9...

Страница 52: ...this appliance Using non listed accessories could result in a safety hazard and will void the warranty 14 14 Appliance Setup Figure 14 1 Install Rear Retainer E Glass Panel Installation CAUTION Risk o...

Страница 53: ...ra 2 lbs may be saved for future use 1 Place media evenly on the base pan Figure 14 9 shows properly placed media 2 The media can only be placed in the shaded areas as shown in Figure 14 7 and Figure...

Страница 54: ...000CMOD IPI 2241 900 Rev K 4 14 54 Figure 14 7 Placement of Media NO MEDIA ON PILOT OPENING WHITE AREA BURNER NO MEDIA ON PILOT OPENING WHITE AREA BURNER Figure 14 8 Placement of Media Figure 14 9 Pro...

Страница 55: ...groove on the glass frame Air Shutter Settings H Install Trim and or Surround Install optional trim kits and or surrounds using the instructions included with the accessory Use non combustible materi...

Страница 56: ...ximately 17 in or 1 8 in 3 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly or depleted batteries Verify that transformer is installed and plugged into mo...

Страница 57: ...sense lead is at least 0 14 microamps Verify correct pilot orifice is installed and gas inlet is set to pressure specifi cations Polish flame sensing rod with fine steel wool to remove any contaminant...

Страница 58: ...to Section 5 Figure 16 1 Appliance Dimensions 6000 Models A B C D E FRONT VIEW TOP VIEW LEFT SIDE RIGHT SIDE F G H I J K L O P GAS LINE ACCESS Q R N Location Inches Millimeters J 21 533 K 11 11 16 297...

Страница 59: ...1 533 K 11 11 16 297 L 35 1 2 901 M 17 3 4 451 N 8 1 2 216 O 2 7 8 73 P 8 1 2 216 Q 1 25 R 42 7 8 1089 Location Inches Millimeters A 48 1219 B 43 1 8 1096 C 35 1 2 902 D 36 5 8 930 E 2 3 8 60 F 9 15 1...

Страница 60: ...7 3 8 in 187 mm 11 3 8 in 289 mm 1 1 4 in 32 mm 9 1 4 in 235 mm 13 1 4 in 337 mm 1 2 in TYP DVP90ST 90 Elbow 10 in 254 mm 10 in 254 mm 1 in 25 mm 12 in 305 mm 14 in 356 mm 1 in 25 mm 8 in 203 mm 6 in...

Страница 61: ...mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness...

Страница 62: ...ick Extension 13 3 4 in 349 mm 5 in 127 mm 13 3 4 in 349 mm Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 356 mm COOL ADD Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12...

Страница 63: ...nation Cap Highwind PVK 80 Not compatible with Intellifire Plus For use with IPI and DSI appliances only 14 in 356 mm 12 in 305 mm 12 1 8 in 314 mm 7 1 8 in 181 mm 8 3 4 in 222 mm 1 5 8 in 41 mm 16 7...

Страница 64: ...G Optional Wire Harness DESCRIPTION PART NUMBER 10 ft PV Wire Harness PVI WH10 20 ft PV Wire Harness PVI WH20 40 ft PV Wire Harness PVI WH40 60 ft PV Wire Harness PVI WH60 80 ft PV Wire Harness PVI WH...

Страница 65: ...6 1 2 in 165 mm 6 5 8 in 168 mm 9 7 8 in 251 mm 6 1 2 in 165 mm 9 1 4 in 235 mm SLP45 45 Elbow SLP90 90 Elbow Effective Height Length SLP PIPE SLP HVS Horizontal Pipe Support SLP FS Ceiling Firestop S...

Страница 66: ...ld SLP TRAP Horizontal Termination Cap 15 1 8 in 384 mm Note Heat shields MUST overlap by a minimum of 1 1 2 in 38 mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm...

Страница 67: ...BER 1 Non Combustible Board 2166 136 2 Refractory Bracket Qty 2 req 2241 115 3 Rock Fixture Assembly 2241 040 Y 4 Base Pan Assembly 2241 015 4 Base Pan Back 2241 114 4 Base Pan Front 2241 101 4 Pilot...

Страница 68: ...PART NUMBER 1 Non Combustible Board 2170 136 2 Refractory Bracket Qty 2 req 2241 115 3 Rock Fixture Assembly 2241 040 Y 4 Base Pan Assembly 2242 015 4 Base Pan Back 2242 114 4 Base Pan Front 2242 101...

Страница 69: ...bly LP 2090 013 Y 12 3 Pilot Bracket 2241 109 12 4 3 Hole Grommet 2118 420 12 5 Valve Bracket 2118 104 12 6 Flex Ball Valve Assembly 302 320A Y 12 7 Valve NG 2166 302 Y Valve LP 2166 303 Y 12 8 Male C...

Страница 70: ...2166 323 Y Fuse for battery pack can be sourced locally not a warranty item Specs are 250v 1A fuse 3 4 long Flue Restrictor 385 128 Gasket Assembly 2166 081 Includes Vent Seal Cap Burner Neck Shutter...

Страница 71: ...________ ________________________________________________________________________________ ________________________________________________________________________________ _____________________________...

Отзывы: