11
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. K • 4/14
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the
fi
replace after 9 hours of continuous
operation without receiving a command from the
RC300 remote.
J. Before Lighting Fireplace
Before operating this
fi
replace for the
fi
rst time,
have a
quali
fi
ed service technician
:
• Verify all shipping materials have been removed from
inside and/or underneath the
fi
rebox.
• Review proper placement of glass panels and media.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT
op-
erate
fi
replace with
fi
xed glass assembly removed.
H. IPI Battery Tray/Battery Installation
The IntelliFire Plus
TM
system has a battery backup option.
Battery longevity and performance will be affected by the
service temperatures of this appliance.
NOTICE:
Batteries should only be used as a power source
in the event of an emergency such as an outage.
I. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.3.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, fuel conversion,
and in the event that the control goes into LOCK-OUT
mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI
fl
ame setting, with no adjustment in
fl
ame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote (RC300).
2. If using a wired wall switch with the module in REMOTE
mode, the
fl
ame output can be adjusted with the HI/LO
selector switch on the module. See Figure 2.3. Note
that the
fl
ame HI/LO selector switch will become inactive
once an optional remote control (RC200/RC300) is
programmed to the control module. Note that the control
module will always ignite the
fi
replace on HI and remain
so for the initial 10 seconds of operation. If the HI/LO
is switched to the LO position, the
fl
ame output will
automatically drop to the lowest setting after the
fl
ame
has been established for 10 sec. After this 10 second
period, the
fl
ame can be adjusted from HI to LO with
the switch.
3. The control module has safety feature that automatically
shuts down the
fi
replace after 9 hours of continuous
operation without receiving a command from the RC300
remote.
4. If you intend to use both an optional wired wall switch
and the RC300 remote control to operate your
fi
replace,
the wall switch will override any commands given by
the remote.
5.
Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying an error code at its status indicator LED.
• Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section H.
Figure 2.3 Control Module
• Locate the module selector switch. (See Figure 2.3).
• Set the module selector switch to the OFF position.
• Wait
fi
ve (5) minutes to allow possible accumulated gas
to clear.
• Set the module selector switch to ON or REMOTE
position.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT
reset the mod-
ule more than one time within a
fi
ve minute time period.
Gas may accumulate in
fi
rebox. Call a quali
fi
ed service
technician.
LP/NG GAS-TYPE
SELECTOR SWITCH
WIRE LEAD FROM
REGULATOR CONNECTS HERE
MODULE
SELECTOR
SWITCH