6
START UP
• Only people trained in the operation and supervision of this heater should operate
and maintain the unit.
• Check the unit to make sure that there are no visible defects on the control and safety devices
and that the unit has been installed correctly.
1. Check that the control switch on the control box is in position “0” (STOP).
2. Pre-select desired room temperature on the remote thermostat. The temperature must be set
higher than the ambient temperature.
3. Open all possible shut-off devices of the fuel supply lines.
4. Turn the control switch on the control box to position “1” (HEATING).
5. When the ambient temperature level is low, the burner switches on automatically. The fan
does not switch on until the set temperature (104ºF) of the heat-exchanger has been
reached (will take approximately 1-5 minutes).
• After startup, the heater is operated automatically by the room thermostat and governed by all
control devices, including the safety limit controls.
• The room thermostat and burner sensor control the running sequences of the
burner and the fan sensor controls the fan function.
• Overheat limit reset controls and shuts off the heater (burner) in the case of overheating.
• The unit can also be used for ventilation purposes only, if needed.
1. Turn the control switch on the control box to position “2” (VENTILATION).
2. The unit is now in the continuous ventilating mode.
3. Heating is not possible in this mode.
SHUT DOWN
• Turn control switch to position “0” (STOP).
• If moving the heater, close fuel supply followed by turning control switch to position “0” (Stop).
Important!
The air supply fan continues running to cool down the combustion
chamber/heat exchanger and then stops later. The fan can restart for several
times before finally switching off!
WARNING!
UNIT MAY BE UNPLUGGED IN EMERGENCY SITUATIONS ONLY. OTHERWISE,
DO NOT STOP THE UNIT BY UNPLUGGING IT. UNIT NEEDS TO COOL
DOWN USING ITS OWN FAN. FAILURE TO COMPLY WITH PROPER SHUT-
DOWN PROCEDURES CAN CAUSE DAMAGE TO THE COMBUSTION
CHAMBER, HEAT EXCHANGER, SAFETY FEATURES AND WILL VOID
WARRANTY.
Содержание VF600
Страница 10: ...9 REFERENCE CHARTS ...
Страница 11: ...10 Propane Orifice Kit PN BIE 3000886 Natural Gas Orifice PN BIE 3006703 ...
Страница 13: ...WIRING CHART 12 ...
Страница 14: ...13 PARTS BREAKDOWN ...
Страница 16: ...15 SPARE PARTS BREAKDOWN VG900 VG600 VG700 ...
Страница 18: ...17 RIELLO BURNER WIRING either 120V or 240V control systems ...
Страница 19: ...18 RIELLO BURNER COMBUSTION HEAD ...
Страница 20: ...19 RIELLO BURNER AIR GATE ...
Страница 21: ...20 RIELLO BURNER COMBUSTION CHAMBER ...
Страница 22: ...21 RIELLO BURNER START UP ...
Страница 23: ...22 RIELLO BURNER DIAGNOSTICS ...
Страница 24: ...23 RIELLO BURNER TROUBLESHOOTING ...
Страница 25: ...VF600 OIL FIRED BURNER ELECTRODE SETTING 24 ...
Страница 26: ...VF600 OIL FIRED BURNER AIR ADJUSTMENT 25 ...
Страница 27: ...VF600 OIL FIRED BURNER PARTS BREAKDOWN 26 ...
Страница 28: ...342 N Co Rd 400 East Valparaiso IN 46383 219 464 8818 Fax 219 462 7985 www heatwagon com ...