SUPERSTOR SOLAR SRCC OG-300 LABEL SET
The following labels must be attached to the relevant valves in the system
in order for it to be considered OG-300 compliant. This page should be
laminated, each label cut from it, punched in the margin at the left hand
side and affixed to the appropriate valve with a wire tie, plastic ties are
inappropriate due to high operating temperatures. Failure to affix these
labels will void the SRCC OG-300 system certification.
VALVE 8
PLEASE CONSULT YOUR INSTALLATION MANUAL FOR SPECIFIC FREEZE
TOLERANCE INFORMATION.
A 60% CONCENTRATION OF DOWFROST HD PROPYLENE GLYCOL AND DISTILLED WATER
CAN PROTECT YOUR SUPERSTOR SOLAR SYSTEM TO TEMPERATURES AS LOW AS -65˚ F.
LOWER CONCENTRATIONS OF DOWFROST HD AND DISTILLED WATER WILL PROVIDE A
LOWER LEVEL OF FREEZE PROTECTION.
VALVE 24
COLD WATER SUPPLY BALL VALVE
THIS VALVE IS NORMALLY OPEN AND ALLOWS POTABLE WATER TO FILL THE SOLAR
STORAGE TANK. WHEN CLOSED, THE SOLAR STORAGE TANK IS ISOLATED FROM THE
PRESSURIZED CITY COLD WATER SUPPLY LINE PIPING.
VALVE 8
COLLECTOR ARRAY FILL/DRAIN VALVE
(WARNING HOT)
VALVE 8 IS NORMALLY CLOSED. WHEN OPEN, IT IS USED TO CHARGE AND DRAIN THE
SOLAR COLLECTOR LOOP PIPING.
THE HEAT TRANSFER FLUID USED IN THIS SYSTEM IS DOWFROST HD PROPYLENE GLYCOL. IT
MUST BE HANDLED AND DISPOSED OF IN ACCORDANCE WITH THE DOW CHEMICAL
COMPANY MATERIAL SAFETY DATA SHEET. A COPY OF THE MSDS HAS BEEN PROVIDED
WITH YOUR INSTALLATION MANUAL. NO OTHER FLUID SHALL BE USED THAT WOULD
CHANGE THE ORIGINAL CLASSIFICATION OF THIS SYSTEM. UNAUTHORIZED ALTERATIONS TO
THIS SYSTEM COULD RESULT IN A HAZARDOUS HEALTH CONDITION.
BE EXTREMELY CAREFUL WHEN DRAINING THIS FLUID. IT MAY BE DISCHARGED AT A VERY
HIGH TEMPERATURE AND/OR PRESSURE.
VALVE 10
COLLECTOR ARRAY FILL/DRAIN VALVE
(WARNING HOT)
VALVE 10 IS NORMALLY CLOSED. WHEN OPEN, IT IS USED TO CHARGE AND DRAIN THE
SOLAR COLLECTOR LOOP PIPING.
THE HEAT TRANSFER FLUID USED IN THIS SYSTEM IS DOWFROST HD PROPYLENE GLYCOL. IT
MUST BE HANDLED AND DISPOSED OF IN ACCORDANCE WITH THE DOW CHEMICAL
COMPANY MATERIAL SAFETY DATA SHEET. A COPY OF THE MSDS HAS BEEN PROVIDED
WITH YOUR INSTALLATION MANUAL. NO OTHER FLUID SHALL BE USED THAT WOULD
CHANGE THE ORIGINAL CLASSIFICATION OF THIS SYSTEM. UNAUTHORIZED ALTERATIONS TO
THIS SYSTEM COULD RESULT IN A HAZARDOUS HEALTH CONDITION.
BE EXTREMELY CAREFUL WHEN DRAINING THIS FLUID. IT MAY BE DISCHARGED AT A VERY
HIGH TEMPERATURE AND/OR PRESSURE.
LP-199-Q
REV. 8/27/07
SOLAR SRCC OG-300 LABEL SET
Содержание Phoenix
Страница 1: ... Installation Operation Maintenance 2007 Heat Transfer Products Inc ...
Страница 31: ...30 WIRING F INTERNAL WIRING PART 6 START UP PROCEDURE CONTINUED Phoenix Connector Diagram ...
Страница 41: ...40 MAINTENANCE NOTES ...
Страница 42: ...41 MAINTENANCE NOTES ...
Страница 43: ...42 MAINTENANCE NOTES ...
Страница 44: ... 2008 2007 Heat Transfer Products Inc www htproducts com LP 179 REV 4 5 08 ...
Страница 68: ...23 ...
Страница 69: ...24 ...
Страница 73: ...28 MAINTENANCE NOTES ...
Страница 74: ...29 MAINTENANCE NOTES ...
Страница 75: ...30 MAINTENANCE NOTES ...