background image

       

 Manufactured for 

Heat 

IQ  

 

to give you years of reliable service, we guarantee it !

Assumes Advanced setting  

A8

 is set to five plus two

  

   

Thank you for purchasing this thermostat from heat IQ we appreciate your business

Programmable Touch screen 

RF

 thermostat  

HIQ 414RF  

and

  415RF 

Specifications 

Power 

2 x AA 1.5V batteries  

Accuracy 

- 0.5 Deg C 

internal Sensor

 - NTC(10K)1% 

Load capacity 

- 5A/240v (BW) 

Switch type 

- Switch relay 

Range of adjustment 

- 5 to 35 Degrees C 

Range of display  

- 0 to 40 Degrees C 

Setting type 

- 5 plus 2 days  

Mounting

 - Wall Surface mounted  or free holder 

(Can fit over standard box, fit Horizontal) 

Dimensions 

 - 130 w 90 h 27 d 

Output switching is Radio Frequency .  reliever  can switch 
voltage up to 5

A

 or, make potential free switching  (typical 

with most boilers or Heat pumps)  

 

Mounting &Wiring instructions 

Install approximately 1.5 m from floor  

Avoid walls subject to direct sunlight  or adjacent to a heat 
source and install 

away from drafts from doors and windows.  

Seal around the  opening into the wall space behind the 
control if drafts present in cavity 

Service Guarantee   (2 years from date of purchase) 

This product was manufactured to our exacting standards .  In case of  failure, no serviceable parts are enclosed, do not open ,return to  

Trade

point

  (

Heat

 IQ

)

 Ltd  

Wanganui New Zealand   [email protected]   or call 

0064 6 3447392   

PO box 530 Wanganui  

Advanced settings  

:   

By

 

Engineer Recommended 

SET 

PRG 

Current temperature and  set point 

Day 

Six daily set points 

Auto  

manual override 

Setting mode 

Time 

Heating on 

touch controls 

Programmed memory is held when screen is off 

Setting and use 

To set clock  time and day  

Press  PRG momentarily, use plus or minus to change flashing setting  
press PRG again to move to next item. 

 

before Setting switch times and temperatures we recommend you write down 
each of the six time and temperatures required for the Mon-Fri and the Sat Sun 
programmes.  You will need to work quickly when entering to avoid the screen 
returning to  the default display

 

 

To set (6) Daily set points  

(

 

Monday to Friday

)

  

Press and Hold PRG   the  first setting  point time will flash set the hour 
and press  PRG to enter...  now set the minutes value  and press PRG to 
enter .... Now set the desired temperature and press PRG to enter

 

You are now at the second set time

.. do as above and repeat until all 

six times  and setting temperatures are entered.  

(Saturday & Sunday) 

As you complete the sixth setting the process will start again for the 
Saturday and Sunday setting  

following  the process as above enter your six weekend set points and 
temperatures

.  

 

You can 

review all settings 

by pressing and holding PRG to enter the 

settings then simply repeat touch PRG to scroll through the settings 

Manual override 

 

Press SET to switch to manual the hand symbol will be displayed  in this 
mode use the +/- buttons to set your desired full time setting. 

 

Temporary override  

at any time you can use +/- to adjust the current set temperature the 
setting will return to default at the next switching  time  

 

Key lock    

Press + & -  for five seconds to lock or  release keys 

Advanced Group 1 settings 

with the thermostat in off 

status  press 

SET 

and

 

together for three to five 

seconds... 

A1

 will be displayed  you can scroll  from 

A1

 to 

A9

 by 

pressing  

SET  -  To adjust parameters use 

 

A1

 

temperature calibration, adjust current 

temperature reading  

A2

 

= stop start switching differential 1 to 5 C. 

A3

 =  

Key lock , when used  0= locked except the on off 

key  1= all keys will be locked  

A4

 

=  

High temp protection switch point 45 Deg 

default, = System off if exceeded 

(not really relevant to 

normal  household uses 

A5 

 Low temperature protection = Auto system on 

switch point 5 Deg C default .Range 5 to 10 DegC   

A6

 =   

Low user setting limit -

Recommend 5 deg C 

A7

 = High user setting limit -

Recommend 25deg C 

A8

 =  Programming type  

7 Days 

6 plus 1 

or  

5 plus 2    

A9

 = Checking Transceiver IP 

Within 10 sec of power on 

press + key quickly to check  transceiver Address will be 
displayed 

 

For further assistance including more advanced 
setting options contact Heat IQ  

REPLACE BATTERIES ANUALY       

Use 

small screwdriver in slots in lower edge to 
remove control from it's back plate  

Requires 2 x AA batteries 

 

See over for 

RF

, receiver wiring details, Pairing set up and Trouble shooting 

Отзывы: