Heat-Flo 115-ST Скачать руководство пользователя страница 1

HEAT-FLO HOT WATER STORAGE/ BOOSTER TANKS

MODELS 30-ST, 40-ST, 40L-ST, 60-ST, 60L-ST

80-ST, 115-ST, 80-ST-C, 115-ST-C

Heat-Flo, Inc.

15 Megan Ct., P.O. Box 612 Uxbridge, MA 01569 USA

Bulletin I0-ST-010115

For service or repairs to the water heater, call your heating contractor.  Your water heater has been manufactured 

to provide years of service.  In order to insure proper service, the following information is provided to assist 

in  enabling  the  installation,  operation,  and  maintenance  of  this  water  heater.    For  your  comfort,  safety,  and 

convenience, we recommend that this water heater be installed and serviced by a plumbing professional.  When 

the installation is completed, keep this manual with the water heater.  Information and specifications outlined 

in this manual in effect at the time of printing of this manual.  Heat-Flo reserves the right to discontinue, change 

specifications, or change system design at any time without notice.

Conforms to UL STD 174 and NSF/ANSI 372

Certified to CAN/CSA STD C22.2 No. 110-94

INSTALLATION, OPERATING, AND 

SERVICE INSTRUCTIONS

Содержание 115-ST

Страница 1: ...ling the installation operation and maintenance of this water heater For your comfort safety and convenience we recommend that this water heater be installed and serviced by a plumbing professional Wh...

Страница 2: ...evere personal injury death or substantial property damage if ignored Indicates the presence of a hazard which can cause severe personal injury death or substantial property damage if ignored Indicate...

Страница 3: ...ion of production of listed equipment or materials as meeting the requirements for Relief Valves and Automatic Shutoff Devices for Hot Water Supply Systems ANSI Z21 22 latest edition This valve must b...

Страница 4: ...with the provided installation instructions Use this water heater only for its intended use as described in this manual Do not use an extension cord set with this water heater If no outlet is availabl...

Страница 5: ...luding L4080B aquastat Brass drain and T P valves are factory installed Dip tubes in tank located to circulate water through the heat source and return to the tank Fully insulated stainless steel tank...

Страница 6: ...water demand dramatically include high flow shower heads hot tubs and the use of more than one shower at a time Increase the tank size if these factors are present Consult ASHRAE sizing guides and ot...

Страница 7: ...iment high or low Ph and high levels of chlorides in the domestic water should be avoided Sediment and hard water will eventually coat the heating coil inside the water heater and reduce the rate of h...

Страница 8: ...a properly sized thermal expansion tank be installed in the cold water inlet line There will be no warranty on applications where there is no pressure control 4 Connect the domestic hot water piping...

Страница 9: ...ting the tank thermostat opens and de energizes the circulator SCALDING This water heater can deliver scalding temperature water at any faucet in the system Be careful when using hot water to avoid sc...

Страница 10: ...the cycle of heating cold water and satisfying at the new lower temperature Additional temperature checks should follow the completion of a heating cycle Further adjustments may be required after you...

Страница 11: ...at the joints unions and shut off valves Repair as required 2 Temperature and Pressure Relief Valve Annual The temperature and pressure relief valve should be checked to ensure that it is in operating...

Страница 12: ...n a Heat Flo anode Severe or rapid deterioration of the anode indicates very aggressive water If this occurs have the water tested to verify whether it is within the limits outlined on page 6 Failure...

Страница 13: ...Heat Flo Inc Hot Water Storage Booster Tanks Page 11 Replacement Parts List...

Страница 14: ...this warranty after a reasonable number of attempts then Heat Flo Inc will provide at its option either a replacement product or a full refund of the purchase price These remedies are the consumer pur...

Страница 15: ...table water with a Ph not to exceed 8 0 and not below 6 0 and or chloride concentrations not to exceed 100 parts per million ppm HFI specifically disclaims liability of any kind resulting from or rela...

Страница 16: ...Heat Flo Inc 15 Megan Ct P O Box 612 Uxbridge MA 01569 USA Phone 508 278 2400 Fax 508 278 2466 e mail sales heat flo com www heat flo com Providing Solutions through Superior Design...

Отзывы: