26
Installing the Stove
(continued)
Installation
(suite)
3. Install Support Brackets
For Horizontal Runs -
The vent system must be
supported every 5 feet (1.5m) of horizontal run by a
horizontal pipe support.
To install support brackets for
horizontal runs:
•
Place the pipe supports
around the vent pipe.
•
Nail the pipe supports to the
framing members.
For Vertical Runs -
The vent
system must be supported
every 8 feet (2.4m) above the
stove vent outlet by wall
brackets.
To install support brackets for
vertical runs:
•
Attach wall brackets to the
vent pipe and secure the
wall bracket to the framing
members with nails or
screws.
Continue adding vent
components, locking each
succeeding component into
place.
Figure 12. Adding
Venting Components
Figure 13. Installing
Support Brackets
Continuer à ajouter des
sections et à les verrouiller
successivement.
Figure 12.
Ajout de sections
Pour poser des supports de
conduit horizontal:
•
Placer les supports autour
du conduit.
•
Clouer les supports dans
les montants de la
charpente.
Sections verticales -
Le
système de ventilation doit
être soutenu par des
supports accrochés aux
murs tous les 2,4 m (8 ft) au-
dessus de l’orifice
d’échappement de l’appareil
de chauffage.
Pour poser les supports de
conduit vertical:
•
Attacher les supports
muraux sur le conduit et
les clouer ou visser sur les
montants de la charpente.
3. Pose des supports de montage
Sections horizontales -
Le système de ventilation doit
être soutenu par un support horizontal tous les 1,5 m (5
ft) de conduit horizontal.
Figure 13.
Pose des supports de montage
WALL
BRACKET
(SUPPORT MURAL)
WALL STUD
(MONTANT DU MUR)
VENT OUTLET
(ORIFICE
D’ÉCHAPPEMENT)
1 INCH MIN.
(25.4mm)
8 ft
(2.4mm)