20
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI • 2120-901 Rev. U • 11/13
5
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traf
fi
c and away from furniture and draperies.
NOTICE:
Illustrations re
fl
ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
K
C
A
L
I
B
G
D
J
J
G
A
F
H
M
Models
A
B
C
D
E
Min.
F
Min.
G
H
I
J
K
L
M
SL-750TRS-IPI-E
SL-750TRS-E
in.
45-1/2
42
64-3/8
See Section
5.D for Alcove
Installation
1
1/2
45-1/2
64-3/8
16-1/4
48-1/2
68-3/4
16-5/8
7-1/2
mm
1155
1067
1635
25
13
1155
1635
413
1232
1737
422
191
SL-550TRS-IPI-E
SL-550TRS-E
in.
42
37
59-1/2
1
1/2
44
62-1/4
16-1/4
48-1/2
68-3/4
15-1/16
7-1/2
mm
1067
940
1511
25
13
1117
1581
413
1232
1737
383
191
SL-350TRS-IPI
in.
39-1/2
34
55-7/8
1
1/2
44
62-1/4
16-1/4
48-1/2
68-3/4
13-1/2
7-1/2
mm
1003
864
1413
25
13
1117
1581
413
1232
1737
343
191