Appliance Clearances (see Page 2 for additional details):

Sides of stove to adjacent surfaces: CAN: 1/8” (3 mm) min.

Rear clearance: 0” to non-combustible wall. 6” (15cm) to
combustible wall. Check local building codes to determine
if wall behind your appliance is combustible or non-com-
bustible.  (Installation of Heartland Splashback Kit will
ensure non-combustible installation clearances apply -
see Splashback Kit Specifications for details).

Top of counter to underside adjacent cabinets: 18” (46 cm)

Cooktop to underside overhead cabinets: 30” (76 cm)

Cooktop to underside vent hood: 30”- 36” max (76-92 cm)

Edge of range to combustible wall on either side: 6” (15 cm)

Cut out width for range’s main body: 36-1/4” (92 cm).

Max. countertop  depth: 25” (63.5 cm) - air intake slots on
underside of control panel must not be obstructed/covered

Max. countertop height: 7-3/4” (21 cm)

Max. overhead cabinet depth: 13” (33 cm)

Note: If unit is installed beside a refrigerator it is important
that there be at least  5" (13 cm) between the refrigerator
and range for proper air circulation.

APPLIANCE REQUIREMENTS

(Optional Splashback Kit: see

Splashback Specifications Page)

Electrical hookup must be performed by a licenced
electrician

120 Volts 60Hz 0.375 Kw.

5 ft (1.5 m) power cord included with 3 prong plug.

Stove must be electrically grounded in compliance with
local codes.  In the absence of local codes, with the
National Electrical code ANSI/NFPA 70 “Latest Edition”
in the US or in Canada with the Canadian Electrical
Code, Part I, CSA Standard C22, or the Local National
Electrical Code.

Appliances installed in the state of Massachusetts
• This appliance can only be installed in the

state of Massachusetts by a Massachusetts
licensed plumber or gas fitter

• This appliance must be installed with a three

(3) foot / 36 inch long flexible gas connector

• A “T” handle type manual gas valve must be

installed in the gas supply line to this appliance

Electrical

Warning

How-to Steps

Cook-top’s support deck must be able to support
220 lbs minimum.

Gas

Materials and installation must be completed in
accordance with all local &national codes.

To eliminate risk of burns or fire, installation of
cabinet storage space above range should be
avoided.  Existing cabinets min clearance  30-
1/4” (76 cm).

Gas cooking appliances produce heat and
moisture - ensure  kitchen is well ventilated.

Heartland Vent Hood Clearances:

Vent Hood to either  side of cabinetry: 0”

Cooktop to underside vent hood: 30”- 36” max
(76-92 cm).

If not utilizing Heartland product: minimum vent-
ing capacity required: 600 CFM

Safety

VENTING REQUIREMENTS

(

Heartland Vent Hood: see Vent

Hood Specifications page)

How-to Steps

Electrical

Installation work and electrical wiring must be
performed  by qualified person(s) in accordance
with all applicable codes and standards including
fire-rated construction.  Electrical connection to
the Vent Hood is to be hard wired by a licensed
electrician - no power cord included.

Maximum ducting run: 45 linear feet - subtract
10' per 90 deg elbow and 5' per 45 deg elbow.
Do not use more than two elbows

.

Flashings & Rain Caps available from your
local Building Supply Center or to be custom
made by your local sheet metal shop (square
rain caps require an equivalent cross sectional
area to the 8” diameter ducting)

Ductwork diameter: 8” (20 cm)

Duct work must be metal, such as
Rigid Galvanized. Do not use plastic
duct.

Heartland’s Standard 36” Vent
Hood: 900 CFM 120 Volts, 60 HZ,
780 Watts

Duct

options

Duct

2nd Floor

Ceiling

Outside

wall

Outside

wall

Recommendation for Superior Venting:

In order to capture higher proportion of  fumes,
we recommend using a 42” hood for a 36”
stove

Vent Hood must be vented
outdoors (see page 2 for details).
Do not exhaust air into spaces
within walls, ceilings, attics, crawl
spaces or garages - where an
accumulation of grease could
become a fire hazard.

Ducting

Safety

Gas hook-up must be performed by licensed

gas fitter.

Natural Gas/Propane Conversion kits avail-

able

from dealer or factory and must be

performed by a licensed gas fitter

Min Pressure requirements: NG: 6” WC; LP gas: 11” WC.

5/8” minimum diameter flex line.

Connection: 1/2” NPT

Accessible manual shut off valve must be installed at the
appliance.

Unit contains pre-set and pre-installed gas regulator.