background image

 

Champlain Model 8302 

     Manual: 6400-40421 

R: 06-15-15

 

Champlain

 

(Model 8302) 

Gas-Fired Direct Vent Heater

                                                                                            

 

Owner’s Manual  

Operation & Installation Guide 

Read This Owner’s Manual 

Operate and Maintain This Gas Heater  

According to This Instruction Manual. 

 

Save These Instructions! 

 

 

 

 

WARNING: FOLLOW THE INFORMATION IN 
THESE INSTRUCTIONS EXACTLY, IF NOT, A FIRE 
OR EXPLOSION MAY RESULT CAUSING 
PROPERTY DAMAGE, PERSONAL INJURY OR 
LOSS OF LIFE. 

 

WARNING: DO NOT STORE OR USE GASOLINE 
OR ANY OTHER FLAMMABLE VAPORS AND 
LIQUIDS NEAR THIS OR ANY OTHER GAS 
APPLIANCE. 

WHAT TO DO IF YOU SMELL GAS: 

  Do not try to light any appliance. 
  Do not touch electrical switches; do not use the phone 

in your building. 

  Immediately call your gas supplier from a phone 

outside the structure

. Follow your gas supplier’s 

instructions. 

  If you cannot reach your gas supplier, call the fire 

department or 911. 

 

A qualified installer, service agency, or gas supplier must 
perform installation and service of this appliance. In the 
Commonwealth of Massachusetts, all installation of gas 
lines and gas fittings must be performed by a licensed gas 
fitter or licensed plumber. 

 

AVERTISSEMENT:  ASSUREZ-VOUS  DE  BIEN 
SUIVRE  LES  INSTRUCTIONS  DONNÉ  DANS 
CETTE  NOTICE  POUR  RÉDUIRE  AU  MINIMUM  LE 
RISQUE  D’INCENDIE  OU  POUR  ÉVITER  TOUT 
DOMMAGE  MATÉERIEL,  TOUTE  BLESSURE  OU 
LA MORT. 

 

AVERTISSEMENT:  NE  PAS  ENTRESPOSER  NI 
UTILISER  D’ESSENCE  NI  D’AUTRE  VAPERURS 
OU 

LIQUIDES 

INFLAMMABLES 

DANS 

LE 

VOISINAGE  DE  CET  APPRAREIL  OU  DE  TOUT 
AUTRE APPAREIL. 

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

 

 

Ne pas tenter d’allumer d’appareil. 

  Ne touchez à aucun interrupteur. Ne pas vous servir 

des téléphones se trouvant dans le batiment où vous 
vous trouvez. 

  Appelez immédiatement votre fournisseur de gaz 

depuis un voisin.  Suivez les instructions du 
fournisseur. 

  Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service dos incendies. 

 
L’installation  et  service  doit  être  exécuté  par  un  qualifié 
installer, agence de service ou le fournisseur de gaz.

 

 

Содержание Champlain 8302

Страница 1: ...service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a licen...

Страница 2: ...pply Connections 18 Gas Connections 19 Initial Leak Check 19 Pre Ignition Checks 19 Initial Lighting Instructions 21 Remote Ignition Instructions 21 Manual Ignition Instructions 21 Pilot Adjustment 22...

Страница 3: ...nt lip lifting slightly and pulling forward free of the stove Set panel aside on a soft surface Locate and grasp receiver body Pull receiver straight forward from the mounting bracket firmly but slowl...

Страница 4: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Страница 5: ...Room 1511 Boston Massachusetts 02202 Manufactured and Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Cham...

Страница 6: ...tter on remote control Part Description 8302 0010NP Matte Black 8302 0020NP Brown Enamel Read this Owner s Manual Operate and maintain this gas heater according to the instructions in this manual For...

Страница 7: ...on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil doit tre atilis uniquement avec les types de gas indiqu s sur la plaque sign...

Страница 8: ...burner material supplied with the Champlain is damaged or parts are missing they must be replaced with the same or approved Hearthstone replacement parts These components affect the combustion qualit...

Страница 9: ...0 et 2000 pieds 0 610 m seulement Items Required for Installation External regulator for propane LP only LP conversion kit for propane only Piping which complies with local codes Pipe sealant approve...

Страница 10: ...ont panel by lifting up and off of the stove body Set aside on a soft surface Figure 3 Front Panel Removal 3 Remove glass by rotating retention clips up until clear of the clip slot Lean the glass awa...

Страница 11: ...S WHICH THROUGH TESTING IN AN INDEPENDENT LABORATORY TO ANSI AND CSA STANDARDS WILL PREVENT FIRE OR SPONTANEOUS COMBUSTION WE DO NOT CONTROL THE COMBUSTIBLE MATERIALS EXPOSED TO HEAT BY THIS PRODUCT T...

Страница 12: ...odel 8302 is approved for installation only with the vent connecting components listed in this manual Use the following instructions along with the pipe manufacturer s instructions to complete the ins...

Страница 13: ...lumbing in the chosen wall location Move the stove and pipe assembly back until the 90 elbow is flush to the wall Ensure the 2 vertical pipe is still parallel to the wall Draw a circle around the pipe...

Страница 14: ...ON VENTING CONFIGURATIONS A minimum of 24 rise is required with or w o offsets 40 maximum system height without offsets Maximum rise to run 1 to 5 The termination must meet the requirements outlined i...

Страница 15: ...Hearthstone Quality Home Heating Products Inc CHAMPLAIN Model 8302 14 Figure 12 Approved DV Venting Alternate Configurations for Vertical Termination...

Страница 16: ...lity Home Heating Products Inc CHAMPLAIN Model 8302 15 Figure 13 Venting Configuration and Restrictor Settings To adjust your restrictor for optimum flame appearance follow the instructions in Restric...

Страница 17: ...m CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center...

Страница 18: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE...

Страница 19: ...R GLEMENTS SELON LES CODES D INSTALLATION CAN CGA B149 NFPA Code and Hearthstone require the use of a dedicated sediment trap just upstream of the unit Damage to the valve or other components due to...

Страница 20: ...rosive leak detection fluid or other approved leak detection method around the diaphragm flanges pipe connections seal cap and all other joints Bubbles indicate a leak 2 If no leakage is detected proc...

Страница 21: ...ows for better line of sight see notice below 3 When the RF receiver is placed in the appliance the surrounding metal can reduce reception considerably The position of the antenna on the receiver also...

Страница 22: ...leak is detected tighten pipe connections including adapters according to GAS CONNECTIONS page 18 Manual Ignition Optional 1 Remove orange ignition wire from Control module and insert onto Piezo Igni...

Страница 23: ...y go out if the pilot flame is too small or misdirected away from the thermopile WARNING THE CONTROL HAS AN INTERLOCK DEVICE IF THE STOVE HAS BEEN LIT IT WILL NOT RELIGHT AGAIN IMMEDIATELY AFTER SHUTT...

Страница 24: ...ockwise until it bottoms out The low pressure orifice must also be changed see figure 22 27 pages 24 25 NOTE Do NOT adjust and or alter any components marked with tamper indicating paint To Switch the...

Страница 25: ...in the valve snug it down until it stops turning by turning clockwise 9 Swing the valve mounting bracket back up into its original position 10 Tighten the two front mounting screws and assure valve b...

Страница 26: ...Gate protruding toward the front of the pilot tower and the letters NAT should be visible on the upper horizontal surface see figure 28 Slide the gate backward in the Pilot Tower by pushing on the up...

Страница 27: ...N OFF switch on the valve to OFF 4 Replace valve access panel 5 Turn the gas supply valve to the off position FINAL CHECK Observe several complete cycles to ensure proper operation During these cycles...

Страница 28: ...s in this section 1 If not already opened follow the instructions for firebox access on page 9 2 Remove the packaging material around the log set assembly Be careful not to damage the log set when unp...

Страница 29: ...cast iron panels are re installed follow start up procedure outlined below Air Shutter The air shutter is used to regulate the air to gas combustion mixture which in turn influences the size and color...

Страница 30: ...tions cannot be corrected through air shutter adjustment an adjustment must be made to the gas supply pressure Supply line manifold gas line pressure adjustments must be performed by qualified service...

Страница 31: ...estrictor Fully Open Detail baffle removed for clarity Figure 36 Restrictor Adjuster Arm Detail Maxitrol GV60 Control System Features NOTE REMOVE THE MODESTY PANEL BELOW THE FRONT CASTING FOR ACCESS T...

Страница 32: ...commended Low battery indicator on handsets with display Battery replacement is recommended after 2 years Batteries Receiver 4 x 1 5V AA quality alkaline recommended Low battery indication frequent be...

Страница 33: ...will ignite after the Main Valve knob is turned past the minimum setting Once the main burner is on continue turning the Main Valve knob until the desired flame height is reached 10 If the Main Burne...

Страница 34: ...tton C to decrease flame height or to set appliance at pilot flame For fine adjustment tap button A or C Designated Low Fire and High Fire Double click small flame button LO will be displayed NOTE Fla...

Страница 35: ...but no flame press and hold the small flame button and turn to Pilot flame NOTE The light bulb icon is displayed during light dimmer setting only 8 seconds after the light dimmer has been set the han...

Страница 36: ...F and adjusts fan speed NOTE To turn OFF fan press small flame until all 4 speed bars disappear Nighttime Setback Temperature Mode Appliance must be in standby mode pilot ignited The room temperature...

Страница 37: ...press SET button to scroll to TEMP mode sun icon Hold the SET button until the set temperature on the screen flashes Press large flame button to increase Daytime Set Temperature Press small flame but...

Страница 38: ...sun icon displayed and the time flashes Set the hour by pressing the large flame button Set the minutes by pressing the small flame button Setting P1 OFF Time Select Timer Mode by briefly pressing th...

Страница 39: ...Day Shut Off CSA version The system shuts off the fire completely if there is no change in flame height for 5 days NOTE Before the next ignition there is a 2 minute waiting period Routine Maintenance...

Страница 40: ...qualified service personnel as described on page 22 Complete the cleaning procedure by carefully placing the log set within the firebox as described on pages 26 28 Reattach the glass and front panel t...

Страница 41: ...ass from the glass frame by drilling out the four 1 8 rivets that lock the glass in place Pull the glass away from the frame and set it aside If replacing gasket only 1 Remove the existing gasket from...

Страница 42: ...XCHANGER BASE 5301 080 OUTLET RESTRICTOR CLIP 2310 860 HEAT EXCHANGER 5701 925H STARTER COLLAR 2310 240 EXHAUST BAFFLE 7000 027 THERMOCOUPLE INTERRUPTER 3030 036 GLASS 7000 360 REMOTE CONTROL 3160 080...

Страница 43: ...will not stay lit after carefully following lighting instructions A Low or too high gas pressure B Faulty connections C Pilot dirty or plugged D Thermocouple damaged E Thermocouple Interrupter circuit...

Страница 44: ...locked the rate at which the exhaust leaves draft determines the rate at which the combustion air is delivered Poor draft results in insufficient air delivery or a restricted exhaust Correct air intak...

Страница 45: ...44 07044 2 RATING LABEL...

Страница 46: ...d will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the original limited warranty or one year whichever is longer Parts Hearthstone will replac...

Страница 47: ...rials ash grates and glass 4 Damage resulting from installation modification alteration repair or service of the appliance by any party other than an authorized Hearthstone dealer a Dealer or their de...

Страница 48: ...ealer service call The Original Purchaser should refer to the Dealer Network search engine contained on Hearthstone s Web site www hearthstonestoves com if the original dealer is not available to find...

Отзывы: