background image

Cleaning Instructions

Before and after each use, clean the thermometer with a soft cloth and 70%
isopropyl alcohol diluted with water, or wash with COLD soapy water. Do not submerge the
thermometer in any liquid. Wipe the thermometer with a dry cloth and allow to air dry.
1. The unit must never be sterilized by boiling, gas or steam autoclaves.
2. The use of any other solution or cleaning method beyond the above mentioned may

result in reliability problems with the thermometer and void your warranty.

Switching Dual Scale

NOTE:

To change between Celcius and Fahrenheit readings, hold the POWER button for 2

seconds until the “Lo” with an “m” displays and changes between °F and °C. Press the
POWER button again to turn the thermometer off.

How to Take Your Temperature

1. Clean the thermometer according the instructions provided.
2. Apply a disposable probe cover to the clean, dry thermometer.
3. Determine whether the measurement site will be oral, rectal or underarm.

NOTE:

Measurement time may vary based on the selected site.

Once the desired temperature is selected, press the POWER button
(the unit will beep) to activate the thermometer. This is the LCD

display test, which insures all parts of the display are functioning
properly.

The last measured temperature with an “m” will appear. If there is no
previous measurement, “Lo” °F(°C) will be displayed.

98.6°F(37.0°C) will briefly appear

Finally, a “Lo” with a flashing °F(°C) will appear in the display to
indicate that the thermometer is ready for measurement.

NOTE:

If the room temperature is above 89.6°F(32.0°C), the room temperature will display

instead of the Lo.

General Care

1. The thermometer should only be used under the supervision of an adult.
2. Do not walk, run or talk during temperature taking.
3. Clean the thermometer before and after each use.
4. Store the unit in the protective case when not in use.
5. Do not bite the probe.
6. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.

Avoid extreme temperatures.

7. Dropping or subjecting your thermometer to strong shocks should be avoided.
8. Do not attempt to disassemble the unit, except to replace the battery.
9. If measurement is not attainable, the unit must be replaced.

NOTE:

Performance of the device may be degraded if: operated outside of stated

temperature and humidity range; stored outside of stated temperature and humidity
range; thermometer undergoes mechanical shock (drop); patient temperature is
below ambient temperature.

Changing the Battery

The battery in your digital thermometer needs to be replaced when the “

” symbol

appears. Replace the battery with two LR1130 or equivalent.

To replace the battery,
1. Remove screw and slide the battery cap away from the unit.
2. Gently pull the battery tray out until it stops. Using a

non-metal pointed tool, carefully remove the batteries and
insert the new batteries with the positive (+) side facing up.

3. Carefully slide the battery cap back into place, making sure

that the cap fits snugly to protect the battery compartment
from moisture and replace screw.

NOTE:

Please properly dispose of the batteries away from children

and heat.

Specifications

Item 15-901-000, 15-902-000, 15-903-000

DISPLAY:

Liquid Crystal Display

DISPLAY RESOLUTION:

4 Digits (1/10TH of a degree increments)

MEASUREMENT RANGE:

90.0

°

F to 109.9

°

F (32

°

C - 42.9

°

C)

ACCURACY:

±0.2

°

F (98.0

°

F - 102.0

°

F) ±0.1

°

C (37.0

°

C - 39.0

°

C)

AVERAGE MEASUREMENT TIME:

Oral 30 seconds. Rectal 20 seconds. Axillary 40 seconds

TONE:

Thermometer barks, moos or quacks when activated and deactivated.
A series of barks, moos or quacks signal when peak temperature is
reached.

MEMORY:

Displays last measured temperature

BATTERY:

Two, LR1130 or equivalent

BATTERY LIFE:

Approximately 1,500 measurements

AUTOMATIC SHUT-OFF:

After approximately 10 minutes

AMBIENT OPERATING TEMPERATURE:

50.0

°

F to 113.0

°

F (10

°

C to 45

°

C)

HUMIDITY:

15% to 95% RH

STORAGE TEMPERATURE:

-4.0

°

F to 122.0

°

F (-20

°

C to 50

°

C)

HUMIDITY:

15% to 95% RH

DIMENSIONS:

Dog: 5.9” x .98” x 1.02”

Cow: 5.7” x 1.14” x .83”

Duck: 5.8” x .94” x .91”

WEIGHT:

Dog: 0.85 ounces (24 grams)

Cow: 0.81 ounces (23 grams)

Duck: 0.77 ounces (22 grams)

Specifications are subject to change without notice.

Taking an Oral Temperature

Approximate measurement time: 30 seconds

1. Using the diagram on the right, place the

probe tip under the tongue as near as
possible to the heat pocket. The diagram
also shows the temperature variables by
not placing the tip in the heat pocket area.

NOTE:

Drinking hot or cold fluids, exercising,

smoking or performing other activities may raise
or lower your temperature. Therefore, it is
important to relax for approximately 5 minutes
with your mouth closed prior to taking a
reading.

2. The current temperature is shown and the

°F (°C) will continue to flash during the reading.

3. When the peak temperature has been reached, the

o

F(°C) will stop flashing

and the thermometer will sound four long barks, moos or quacks if the
temperature is below 100

o

F(37.8°C). If the temperature is above 100

o

F(37.8°C)

the unit will sound two sets of three short barks, moos or quacks.

4. To turn the unit off, press the ON/OFF button. The unit will automatically shut off after

approximately ten minutes.

NOTE:

The mouth must remain closed during the measurement for the most

accurate reading. Opening the mouth could result in an extended measurement time and may
affect the reading.

PROBE COVER ORDER FORM

CUT OUT AND MAIL TO:

HEALTHSMART

1931 NORMAN DRIVE SOUTH
WAUKEGAN, IL 60085

Please send

packages of disposable probe covers

#15-618-000 (100 probes per package). Enclosed is $5.00 per
package plus $3.00 for shipping and handling for each order.

PAYMENT METHOD (do not send cash):

Check

Money Order

Please ship to:

NAME:

ADDRESS:

CITY:

STATE:

ZIP:

PHONE: (

)

CUT OUT AND MAIL TO:

HEALTHSMART

1931 NORMAN DRIVE SOUTH

WAUKEGAN, IL 60085

THERMOMETER WARRANTY REGISTRATION

(MUST BE COMPLETED WITHIN 10 DAYS OF PURCHASE)

NAME:

ADDRESS:

CITY:

STATE:

ZIP:

PURCHASED FROM:

CITY:

STATE:

ZIP:

DATE PURCHASED:

MODEL PURCHASED:

15-901-000

15-902-000

15-903-000

USER INFORMATION (OPTIONAL)

MALE

FEMALE

AGE:

AGE OF YOUNGEST FAMILY MEMBER

UNDER 6 MONTHS

6 MONTHS - 1 YEAR

1 - 3 YEARS

3 - 5 YEARS

OLDER

PROBE TIP

BATTERY COVER

(Animal May Vary)

HEAT

POCKET

HEAT

POCKET

98.4

o

F

36.9

o

C

98.4

o

F

36.9

o

C

98.8

o

F

37.1

o

C

98.8

o

F

37.1

o

C

97.9

o

F

36.6

o

C

97.7

o

F

36.4

o

C

97.9

o

F

36.6

o

C

98.1

o

F

36.7

o

C

#91-032-901 01/11

©2011 Briggs Medical Service Company

NOTE:

This order form is for shipments within the United States and Canada.

Thank you for purchasing a HealthSmart Kids Digital Thermometer. Please read the
following detailed instructions to achieve the most accurate temperatures and safe
operation. With proper care and use, your thermometer will provide you with reliable
readings.

What is a “Normal” Temperature?

Although the generally accepted “normal” temperature reading is 98.6°F (37.0°C),
temperature readings can vary from 97°F (36.1°C) to 99°F (37.2°C) and still may be
considered “normal”. Variations in temperature can be attributed to activities such as
exercise, smoking, eating and drinking. Even time of day may influence your temperature.
For example, your temperature is lower in the morning than in the afternoon. Other
variations may be due to the location of the temperature reading. While the oral
temperature follows the guidelines previously described, a rectal temperature is
generally 1.0°F (0.5°C) higher. Conversely, an axillary (under the arm) temperature will be
1.0°F (0.5°C) lower.

Features of your Digital Thermometer

Taking an Axillary Temperature (under the arm)

Approximate measurement time: 40 seconds

1. Wipe the underarm with a dry towel.
2. Place the probe tip under the arm so the tip is touching the skin with the

thermometer perpendicular to the body.

3. Position the arm across the chest so the probe tip is well covered by the arm. This also

insures the probe is not affected by the room’s air.

4. When the peak temperature has been reached, the

o

F(°C) will stop flashing

and the thermometer will sound four long barks, moos or quacks if the
temperature is below 100

o

F(37.8°C). If the temperature is above 100

o

F(37.8°C)

the unit will sound two sets of three short barks, moos or quacks.

5. To turn the unit off, press the ON/OFF button. The unit will automatically shut off after

approximately ten minutes.

NOTE:

Axillary temperatures are generally 1.0

°

F (0.5°C) lower than oral readings.

Taking a Rectal Temperature

Approximate measurement time: 20 seconds

NOTE:

Rectal temperatures are an appropriate and reliable method for infants and small chil-

dren. Otherwise, this method should only be used when it is impossible or impractical to take
an oral or axillary temperature.

1. After applying the disposable probe cover, apply a water-soluble lubricant to

the tip.

2. Gently insert the probe a MAXIMUM of 1/2” into the rectum.
3. When the peak temperature has been reached, the

o

F(°C) will stop flashing

and the thermometer will sound four long barks, moos or quacks if the
temperature is below 100

o

F(37.8°C). If the temperature is above 100

o

F(37.8°C)

the unit will sound two sets of three short barks, moos or quacks.

4. To turn the unit off, press the ON/OFF button. The unit will automatically shut off after

approximately ten minutes.

NOTE:

Rectal temperatures are generally 1.0

°

F (0.5°C) higher than oral readings.

Using Disposable Probe Covers

It is recommended to use the enclosed disposable probe covers to prevent cross
contamination. Additional probe covers can be purchased from your retailer or with the
order form provided.

DIGITAL DISPLAY WINDOW

ON/OFF BUTTON

LIMITED FIVE-YEAR WARRANTY

The warrantor guarantees that this Thermometer will be free from manufacturing defects
under normal use for five years from the original purchase date. This warranty covers only
normal use, and does not apply to use in any clinical or commercial applications. This
warranty does not cover batteries that may be provided with or used with the
Thermometer. This warranty is voided if the Thermometer product is misused or abused
in any manner.

If the Thermometer fails to operate during the first five years from the time originally
purchased, please call our Customer Care Help Line at 800-622-4714 and we will try to
resolve the issue as soon as possible. If the warrantor determines the unit failed to
operate due to a manufacturing defect, the unit will be replaced at the option of the
warrantor. Replacement is the sole remedy under this limited warranty. This warranty
gives you specific legal rights, which vary from state to state. As a condition of this
warranty, the enclosed warranty registration card must be completed and sent to us
within 10 days of the purchase date or can be filled out online at www.mabisdmi.com.

This warranty constitutes the warrantor’s only responsibility and obligation to replace
materials or components. We make no other express or implied warranties, arising by
operation of law or otherwise, or any warranty of merchantability or fitness for a
particular use or purpose whether or not the use or purpose has been disclosed to
the warrantor in specifications, drawings or otherwise, and whether or not the
warrantor’s products are specifically designed and/or manufactured by the
warrantor for the buyer’s use or purposes, except for the limited warranty stated
above. The warrantor will not be responsible for any indirect, incidental, special,
consequential, or punitive damages or other loss, including, but not limited to,
damage to or loss of other property or equipment and personal injuries, whether to
purchaser or others. The warrantor shall in no event be liable to the purchaser for any
amount in excess of the cost of replacement of the unit.

Animal Sounds Digital Thermometer

Item 15-901-000, 15-902-000, 15-903-000

Отзывы: