background image

 

I

I

n

n

s

s

t

t

r

r

u

u

c

c

t

t

i

i

o

o

n

n

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

Automatic 

Wrist Blood Pressure Monitor 

 
 

 

 
 

M

M

o

o

d

d

e

e

l

l

 

 

N

N

o

o

.

.

 

 

H

H

L

L

1

1

5

5

8

8

L

L

D

D

 

 

 
 
 

Содержание HL158LD

Страница 1: ...1 I In ns st tr ru uc ct ti io on n M Ma an nu ua al l Automatic Wrist Blood Pressure Monitor M Mo od de el l N No o H HL L1 15 58 8L LD D ...

Страница 2: ...s 08 Device Overview 10 Symbol Definitions 12 Features 13 Installing Batteries 18 Applying the Cuff 19 Positioning Guide 20 Measurement Procedure 21 Memory Function 23 Bluetooth Transmission 24 Storage and Maintenance 25 Troubleshooting 26 Warranty Recalibration 27 Specifications 28 Note 30 Appendix 32 Blood Pressure Diary 34 ...

Страница 3: ...olic blood pressure and heart rate by using the oscillometric method All values can be read out in one LCD panel Measurement position is at human being s wrist The intended use of this over the counter device is for adults aged 18 years and older with wrist circumference ranging from 5 3 inches to 7 7 inches approx 135 mm to 195 mm and for home use HL158LD detects the appearance of irregular heart...

Страница 4: ...m the afternoon to the evening It is on average lower in the summer and higher in the winter B Why is it useful to measure blood pressure at home Having one s blood pressure measured by a doctor in a hospital or a clinic is often associated with a phenomenon called White Coat Hypertension where the patient becomes nervous or anxious thus raising his blood pressure There are also numerous other fac...

Страница 5: ...d pressure Individual blood pressures vary greatly both on a daily and a seasonal basis These variations are even more pronounced in hyper tense patients Normally the blood pressure rises while at work and is at its lowest during sleeping period hyper tense means a person who has high blood pressure symptom The graph below illustrated the variations in blood pressure over a whole day with measurem...

Страница 6: ... the wrist Within the cuff is a gauge which senses the fluctuations oscillations in pressure The fluctuation measured represents the degree of intensity that your arteries contracting with each heart beat and also a result of the pressure that the cuff has placed on the wrist The monitor measures these contractions and converts the information to a digital value This is the result displayed on the...

Страница 7: ...c Wrist Blood Pressure Monitors have performed equivalent to measurements taken with this scientific device and are within the accuracy limits prescribed by the American National Standard for Electronic or Automated Sphygmomanometers The SPHYGMOMANOMETER was clinically investigated according to the requirements of ISO 81060 2 2013 In case it is needed to have the device checked for calibration ple...

Страница 8: ...garettes Rest at least 5 10 minutes before taking a measurement To allow your blood vessels to return to the condition prior to taking the measurement please wait at least 3 5 minutes in between measurements You may need to adjust the wait time according to your personal physiological situation We recommend you using the same wrist preferably the left wrist and measuring around the same time each ...

Страница 9: ...symptoms should not last long However if you do not recover in time please seek your medical practitioners for help Precautions For those who have had mastectomy surgery especially lymph nodes removed it s recommend take a measurement on the unaffected side When used among medical electronic equipment on the same limb pressurization of the cuff may cause temporarily malfunction to other device If ...

Страница 10: ...s START STOP BUTTON AAA LR03 1 5V ALKALINE BATTERY X 2 STORAGE CASE Caution Substitution of a component different from that supplied might result in measurement error SET BUTTON MEMORY BUTTON BP CATEGORY INDICATOR MODE BUTTON LCD DISPLAY ...

Страница 11: ...rt Rate Low Battery Symbol Memory Record Number Blood Pressure Unit Month Date Hour Minute Also represents YEAR in Setting Mode Pulse Symbol Diastolic Rate Systolic Rate BP Category Indicator Irregular Heartbeat Detector Bluetooth Symbol ...

Страница 12: ... symbol appears for 1 minute when the user was talking moving shaking or an irregular heart beat was detected during measurements Our suggestion Please do not talk or move during measurements Repeat the measurement after resting for at least 5 minutes and restart your measurement while sitting down comfortably and quietly Bluetooth Symbol LCD displays this symbol when Bluetooth Function turns ON B...

Страница 13: ...sually this is not a cause for concern however we recommend you consult with your physician for proper diagnosis or seek medical advice according to our recommendation mentioned above Please note that the device does not appropriate to diagnose hypertension and it is only for user reference on blood pressure monitoring Stages of Blood Pressure Levels Systolic mmHg Diastolic mmHg Color Recommendati...

Страница 14: ...arity is detected during measurement often we recommend you seek medical advice As a safeguard we recommend that if you have arrhythmias such as atrial or ventricular premature beats and atrial fibrillation or any other special conditions you should check with your physician before using your device The IHB function is not designed for use by people with arrhythmias nor for diagnosing or treating ...

Страница 15: ...omplies with electromagnetic compatibility EMC standard of IEC 60601 1 2 EN 301 489 1 EN 301 489 17 EN 300 328 and U S federal guidelines Part 15 of the FCC Federal Communications Commission rules for devices with RF capability These guidelines help ensure that your device will not affect the operation of other nearby devices Additionally other devices should not affect the use of your device Othe...

Страница 16: ...llowing steps for installing 1 To install DailyChek FREE APP go to the Google Play TM APP store and search for DailyChek 2 Click the INSTALL button Once installed click on DailyChek APP icon 3 Now you can start using your Android version or iOS version of DailyChek APP with Bluetooth feature it s a simple tool to log track and trend your test results from your Bluetooth enabled Device Note 1 Daily...

Страница 17: ...ion Batteries are hazardous waste Do not dispose of them together with the household garbage Please discard worn out batteries to the recycling site according to local regulations Keep the battery away from children in case they choke on it To prolong the battery life and prevent damage caused by leakage remove the batteries from the device if the device is not to be used for a long period The dev...

Страница 18: ...it too tight Fold the remaining part of the cuff back out of the way Leave approximately 0 4 inch 10 mm between the cuff and the bottom of your hand palm Note Do not use this device if your wrist has any wound or injury Do not wrap the cuff around any body part other than your wrist In case the cuff kept pumping up no stop open the cuff at once 0 4 inch 10 mm 5 3 7 7 inch approx 135 195 mm ...

Страница 19: ...our feet flat on the floor and lay your forearm on the table make sure your back and arm supported legs uncrossed 2 Position the blood pressure monitor on your wrist 3 Place your elbow on the table and rest the back of your hand on the device storage case or other object 4 Rest your wrist on the armrest until it s at the same height as your heart 5 Relax your hand and turn your palm upwards ...

Страница 20: ...E 1 2 3 31 HOUR 1 2 3 12PM 1 PM 12 and MINUTE 00 01 02 03 59 as described in Step A above D When settings are done press button to confirm the above settings The device is ready to measure Turning Bluetooth Feature ON OFF User can press and hold button 3 seconds to turn the Bluetooth feature ON OFF in Standby Mode Note The Bluetooth Feature Switch default setting is ON Once Bluetooth Feature turns...

Страница 21: ...you C After inflation of the cuff the pressure will slowly decrease When pulse is detected PULSE SYMBOL flashes Note If the cuff does not stop inflating remove the cuff at once To stop measurement press button The cuff will deflate immediately after the button is pressed D LCD screen displays your systolic rate diastolic rate pulse BP Category Indicator Bar and Irregular Heartbeat Detector symbol ...

Страница 22: ...3 measuring results first B Press button again LCD displays the latest measuring result Use button to scroll through all stored measuring results Year and Date Time display alternate automatically C To stop reading memories press button and switch to Standby Mode Erasing data A Press button to enter Memory Mode B Press and hold and buttons at the same time the data will be erased automatically C T...

Страница 23: ...ce and starting Bluetooth function Bluetooth Symbol flashing 2 While transmitting the reading to your Bluetooth enabled Device HL158LD Bluetooth Symbol will remain steady on the screen 3 HL158LD can only pair up with one Bluetooth enabled device at a time To transmit measuring results to other Bluetooth enabled device please retry as mention above Date Time Synchronization 1 The BPM s Date Time Se...

Страница 24: ...ff due to substitution of a component different from that supplied might result in measurement error If any suggestion or service is requested please consult your service station Do not implement the maintenance procedures for equipment during measurement Only trained technicians are allowed to repair and dissemble the device including software upgrades patches and maintenance Note Water quality r...

Страница 25: ...exceeding 300 mmHg Switch the unit off then measure again Measuring Error Symbol Can t determine blood pressure measurement data Wrap the cuff properly and keep steady Measure again BPM cannot communicate with Bluetooth device Paring has not been completed Please re pairing the BPM and Bluetooth device with each other Bluetooth function is not turn on Please refer to Page 21 Measurement Procedure ...

Страница 26: ...s or modifications improper use of electrical power supply loss of power dropped product malfunction or damage of an operating part from failure to provide manufacturer s recommended maintenance transportation damage theft neglect vandalism or environmental conditions loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair or any other conditions wha...

Страница 27: ...es Excluded 97 5 g 10 g 3 44 oz 0 35 oz Cuff Size 135 195 mm approx 5 3 7 7 inch Storage Transportation Environment Temperature 25 C 70 C 13 F 158 F Humidity 93 R H Operation Environment Temperature 5 C 40 C 41 F 104 F Humidity 15 93 R H Atmospheric pressure 700 hPa 1060 hPa Power Supply DC 3 V AAA LR03 1 5V Alkaline Battery x 2 Battery Life Approx 200 Measurements Product Life 5 Years 4 times per...

Страница 28: ...ity AES 128 and application layer user defined Wireless Operation Distance Class 2 Maximum 10 meter RF Frequency Need for Spectrum Management 2402 2480 MHz allowing for guard bands Maximum Limitation Unlimited Maximum Permitted Power 5 mW Proximity of Other In band Transmitters Used in Vicinity up to 40 bands 2 MHz spacing centered from 2402 to 2480 MHz Wireless Communication Profile GATT Client a...

Страница 29: ...rals such as antenna cables and external antennas should be used no closer than 30cm 12 inches to any part of the device Otherwise degradation of the performance of this equipment could result Waste of electrical and electronic equipment WEEE Discard the used product to the recycling collection point according to local regulations Serial number YYMMXXXXXX Ingress Protection Rating First characteri...

Страница 30: ... not expressly approved by the grantee of this device could void the user s authority to operate the equipment RF exposure warning 1 The equipment complies with FCC RF exposure limits set forth for an uncontrolled environment 2 The equipment must not be co located or operation in conjunction with any other antenna or transmitter FCC Label Compliance Statement This device complies with Part 15 of t...

Страница 31: ...c purposes Harmonic emissions IEC 61000 3 2 Not Applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Not Applicable Guidance and manufacturer s declaration electromagnetic immunity The device is intended for use in the electromagnetic environments listed below and should only be used in such environments Immunity test IEC 60601 test level Compliance level Electromagnetic environment gui...

Страница 32: ...cy of the transmitter Radiated RF IEC 61000 4 3 Proximity fields from RF wireless communications equipment IEC 61000 4 3 10 V m at 80 2700 MHz AM Modulation And 9 28V m at 385 6000MHz Pulse Mode and other Modulation The system shall be tested as specified in IEC60601 1 2 Table 9 for proximity fields from RF wireless communications equipment using the test methods specified in IEC 61000 4 3 10 V m ...

Страница 33: ... Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse P N 323102946 VER A002 YYYYMMDD ...

Отзывы: