10.9 RipCord Webbing Replacement
Replacement of a RipCord Webbing assembly may be carried out with the
QuickFlight in place or removed and secured to a workbench.
To replace a RipCord Webbing:
1. Disconnect both Webbing Connection Rings from their respective Upper
Webbings.
2. Cut the connection points off of the RipCord Webbing to ensure it is not
accidentally re-used.
3. Discard the RipCord Webbing and all associated Webbing Connection
Rings, Carabiners, and other connectors unless the manufacturer’s instruc-
tions allow for longer-term use.
ALUMINUM CARABINERS AND RINGS HAVE A LIMITED LIFESPAN AND SHOULD BE
RETIRED FROM SERVICE WHEN THE RIPCORD WEBBING IS REPLACED.
4. Open the Webbing Connection Rings on the new RipCord Webbing.
5. Connect the Webbing Connection Rings so that they each join one Rip-
Cord attachment point to one Upper Webbing attachment point. Ensure
that the OPA end of the RipCord Webbing is attached to the Upper Web-
bings, and that the hand grip and carabiners are positioned away from the
device. It does not matter which Connection Ring goes to which Upper
Webbing.
6. Close the Webbing Connection Rings on the new RipCord according to the
Manufacturer’s instructions.
Webbing
Connection Rings
(see manufacturer’s
instructions)
Webbing Connection Ring Diagram