7 Cleaning and maintaining the heating system – Procedure
76
7.2 Procedure
G
ENERAL
SAFETY
INSTRUCTIONS
Warning!
Danger of asphyxiation due to carbon monoxide!
If the boiler is in operation, carbon monoxide can be emitted
through the open doors, lids or other cleaning openings.
When performing cleaning and maintenance work, do not leave the
cleaning openings, doors and lids open any longer than necessary.
Caution!
Danger of burns from hot surfaces!
During operation, the boiler surfaces under the cladding are hot.
Even when turned off, they only cool down slowly.
Switch the heating system off and only start with the cleaning and
maintenance work when the surfaces have cooled down.
Warning!
Danger of fire!
When the heating system is in operation, open doors and lids
constitute a fire danger.
Always keep the doors and lids closed. Only open them when the
boiler is burnt out. Do not leave them open any longer than
necessary and never leave them open unsupervised.
Warning!
Danger of fire from combustion residue!
The combustion residue (ash,coal, etc.) can catch fire again after
being removed from the boiler.
Let the combustion residue cool off before you vacuum and put the
ashes in an appropriate, non-flammable container.
Caution!
Before the start of the cleaning and maintenance tasks, the display
of the HDG Lambda Control 1 must show the message “
Heat
production off
”.