33
©HBS Bolzenschweiss-Systeme GmbH & Co. KG
All rights reserved – Reprinting, in whole or in part, only with the approval of the manufacturer
11 Connection
Connect the ground clamps
Remove rust, paint and dirt from the points on the work-
piece to which you wish to connect the ground clamps.
Attach the ground clamps to the workpiece as tightly as
possible.
Pay attention to a good contact and symmetrical connec-
tion.
The welding point should be in the middle between the two ground
clamps.
When welding in the insulation area the following must be observed:
Connect the ground clamp
Remove rust, paint and dirt from the points on the work-
piece to which you wish to connect the ground clamp.
Attach the ground clamp to the workpiece as tightly as
possible.