Installation
34
A4500-1.1
HBM: public
WTX120
Profibus status LEDs
Status
Significance
Red
No bus communication
Green
Successful bus communication
Tab. 5.8
D601 System failure (red/green)
5.9.1
Configuration of Profibus DP
In the Profibus device variants, the WTX120 works as a
Profibus-DP slave, forming an I/O interface with up to 64
inputs and outputs, or as a data interface with up to 64
input words and 64 output words, and at a speed of 12
MBit/s.
The Profibus address is set in “Service Mode/Config.
Fieldbus”.
To set the WTX120 Profibus DP variant parameters, a
GSDML file is required which you can download from our
website
www.hbm.com/de/6304/wtx120-industrielles-
5.10 Connection of the Ethernet/IP device
variant
Two RJ45 sockets are provided on the front for connec
tion to an Ethernet/IP network. This enables a star or lin
ear topology to be constructed.
The internal switch required for a linear topology is in
cluded in the WTX120.