Application
WTX110
A4774-1.0
HBM: public
117
As soon as the level rises back above the threshold, the limit switch status is
reset.
Hysteresis (
Hysteresis
)
In Below level mode, the hysteresis specifies the amount by which the level
must exceed the threshold for the limit switch status - and so also the digital
output - to be reset.
8.2.3
Mode: Outside band (
Outside band
)
Weight
Time
Output
Lower limit
Band span
Lower limit (
Low lim
) / Band span (
Band spn
)
In Outside band mode, Lower limit and Band span define a band. Outside that
band, the relevant limit switch status is set. The limit is then likewise set on a
preconfigured digital output (e.g.
output 3 GW1
).
As soon as the weight is back in the band, the limit switch status is reset.