Mechanical installation
T40B
A03452_15_X00_00
HBM: public
21
without rotational speed
measuring system
with rotational
speed measuring
system
Flange plane faces
Transmitter winding
Rotational speed measuring system
Measuring
zone
Fig. 5.1
Bolted rotor connection
1. Prior to installation, clean the plane faces of the transducer flange and the
counter flange.
For safe torque transfer, the faces must be clean and free from grease. Use
a piece of cloth or paper soaked in solvent. When cleaning, make sure that
you do not damage the transmitter winding or the rotational speed measur
ing system.
2. For the bolted rotor connection (
), use six or eight DIN EN ISO
4762 hexagon socket screws of the property class stated in Tab. 5.1, in a
suitable length (dependent on the connection geometry,
We recommend DIN EN ISO 4762 socket head cap screws, blackened,
smooth‐headed, permitted size and shape variance in accordance with DIN
ISO 4759, Part 1, product class A.
3. Fasten all screws with the specified torque (
).
4. There are six or eight tapped holes on the rotor for continuing the shaft train
mounting. Again use screws of property class 10.9 or 12.9 and tighten them
with the prescribed torque, as specified in
Содержание T40B
Страница 1: ...Mounting Instructions Montageanleitung English Deutsch T40B ...
Страница 3: ...Mounting Instructions Montageanleitung English Deutsch T40B ...
Страница 48: ...Maintenance 46 A03452_15_X00_00 HBM public T40B 10 Maintenance T40B torque flanges are maintenance free ...
Страница 70: ...Supplementary technical information 68 A03452_15_X00_00 HBM public T40B ...
Страница 71: ...Mounting Instructions Montageanleitung English Deutsch T40B ...
Страница 163: ...Dimensions Abmessungen T40B A03452_15_X00_00 HBM public 93 ...