144
Functions and outputs
HBM
QuantumX
7
Functions and outputs
The MX878, MX410 and MX460 modules enable
mathematics functions
to be performed
in real time and their results to be provided as
standard system signals
. These system
signals can be used like actual measurement signals for subsequent tasks (analog output,
EtherCAT signal, source signal for mathematics function, data visualization and storage).
The MX878 and MX410 modules feature
analog outputs
that can be connected to a
system or source signal
, for example an actual measurement signal (additionally scaled,
filtered) or the result of a mathematics function.
Measurement channels that are used in mathematics functions or directly for analog outputs
need to be activated for
”isochronous data transfer”
(e.g. in the QuantumX
−
Assistant
software, ”Signals” tab).
Note
The module configuration is immediately active after system reboot (Auto Startup). No
operating PC is required for configured signal outputs to run stand
−
alone.
Mathematics functions at a glance:
S
Peak values (Peak)
S
+
−
x =
Add & Multiply
S
Root mean square (RMS)
S
Vibration analysis (Rotational Analysis) and angle difference (Angle diff)
S
. . .
. . .
Matrix
Mathematics functions provided by the modules
MX410
MX878/MX879
MX460
+
−
x =
min
max
. . .
. . .
Содержание QuantumX MX1609
Страница 1: ...I3031 8 0 en Operating Manual ...
Страница 2: ...d ...
Страница 31: ...31 Housings HBM QuantumX Fig 4 2 Amplifier MX1609 P in IP65 housing ...
Страница 34: ...34 Housings HBM QuantumX a f 2 5 Fig 4 7 Mounting the CASEPROT ...
Страница 36: ...36 Housings HBM QuantumX Fig 4 10 Attaching the covers ...
Страница 38: ...38 Housings HBM QuantumX Fig 4 13 Close the lever Fig 4 14 Connected housings ...
Страница 99: ...99 Connection HBM QuantumX Connection of the thermocouple plug in the miniature design ...
Страница 144: ......
Страница 180: ...179 Support HBM QuantumX ...