PME-MP70DP
66
A0658-7.3 en
HBM
10.5.1 Defining separate configuration combinations
9 configuration entries are available in total. The first entry is reserved for the
MP70 module, the subsequent 8 entries are assigned to the measurement
modules connected to the MP70 module. The special identification format
(special format) must be used here. The manufacturer‐specific data specify
the content and thus also the length of the input data, and are 3 or 9 bytes
long, depending on the module type.
CFG entry no.
Meaning
Content
0
Module 1
to
module 8
Special format with input and output, 9‐word maximum out
put, 13‐word maximum input,
2 - 8 bytes comment length (data)
The subsequent input and output data can be configured for cyclic data
communication. The choice of which data will actually be transmitted, is
communicated via the manufacturer‐specific data of the special identification
format.
Configuration for modules MP30, MP55, MP60 and MP70
Configuration of
manufac
turer‐specific
data
Length of
cyclical data
inputs
Length of
cyclical data
outputs
Cyclical data content
Byte no.
Bit no.
(words)
(words)
0
0..7
0
0
Module type (MP70=0, MP55 =
1, MP60 = 2)
Input values:
1
0
1(2)
Gross
1
1
1(2)
Net
1
2
1(2)
Max
1
3
1(2)
Min
1
4
1
Peak‐to‐peak
1
5
2
Status
1
6..7
0
reserved
Output values:
2
0
1
Control word
2
1
1(2)
Limit value level 1
2
2
1(2)
Limit value level 2
2
3
1(2)
Limit value level 3
2
4
1(2)
Limit value level 4
2
5..7
0
reserved
Tab. 8.1:
Selecting data content via manufacturer‐specific data