PME-MP70DP
18
A0658-7.3 en
HBM
4.2
Supply voltage and control inputs/outputs
With the MP70DP, two removable plug terminals are available for connection,
and with the S7 versions, there are four plug terminals.
0 V
SYN
L
H
Plug terminal 1
Connecting the voltage
supply:
The MP70DP module must be connected to an external
supply voltage of 18-30 V (24 V
nom
).
WARNING
D
Twist the voltage supply cable terminations and attach wire
end ferrules.
D
Screw the cable terminations to plug terminal 1.
D
Insert the plug terminal into the top socket.
D
Switch on the voltage supply.
ATTENTION
Should the mains power fail in the MP70DP module, all control
outputs will be set to 0 V.
24 V
Labeling
Plug terminal 2
Analog OUT
"
10 V
"
20 mA
4 - 20 mA
IN1
IN2
IN3
IN4
0 V
24 V
OUT1
OUT2
OUT3
OUT4
Plug terminal 3
*)
Plug terminal
4
*)
IN 1-4 = digital input
For more detailed information on inputs and outputs, see chapter
‐, page 8.
Labeling
Labeling
*)
for
MP70DPS7
and
MP70S7
only
OUT1-4 = digital output
Fig. 4.1:
Plug terminal assignment
The plug terminals are coded, to prevent confusion when plugging them into
the 2 (4) sockets. The sockets are fitted with coding tabs, the plug terminals
with coding pins.
Содержание MP70DP
Страница 1: ...A0658 7 3 en Profibus interface for the PME MP70DP MP70DPS7 MP70S7 Operating Manual ...
Страница 2: ......