43
PME-MP60/MP07
A0616-13.4 en
HBM
Group
Parameters
Meaning
LIMIT VAL.
1...4
Source
You can select one of the following as the source of the limit
value signal: Gross, Net, Peak value Max/Min/Peak-to-peak
SwtchDir
Value
Hyst
Hyst
Value
Over limit
Below limit
Hyst
24 V
0 V
24 V
0 V
LVS1, ON
LVS2, ON
LVS1 ON
LVS2 ON
Functions and parameters of limit values
OFF
OFF
Value
OnDelay
ms
Starting delay; if the limit value level is exceeded, this change
only has an effect at the output after the delay time (OnDelay).
OffDlay
ms
Cut-off delay, as OnDelay
PEAKVAL.
STORE
1
)
InputMin/
Max
You can select one of the following as the source of the peak
value signal: gross, net
ClearPkV
The peak value can be deleted.
kNm/s Discharge rate (in physical unit/sec) of the envelope function
for both peak-value memories.
Peak-value memories can also be used for displaying
envelope curves. The envelope function is suitable for
measuring amplitude-modulated oscillations. The discharge
rate (time constant of the discharge function) defines how
fast the peak-value memory drops to the current value.
Discharge rate=0 V/s
Discharge rate=1 V/s
V
i
, V
o
t
1)
See also the following page (remote controls)