Manual parameterization and configuration
ML77B
A00760_09_E00_00
HBM: public
49
6
Bit0..3
Decimal places for subchannel 7
6
Bit4..7
Decimal places for subchannel 8
11.1.4 Parametrisation entry for 32-channel device
Byte no.
Bit no.
Meaning
Default
0
Bit 0..3
Type: 32-channel
3 (const)
0
Bit 4..7
Data format
0 = Signed16 2 Byte
1 = Signed32 4 Byte
2 = Float (IEEE-format) 4 Byte
3 = Float (Siemens-format) 4 Byte
4 = Raw data (0..7680000) 4 Byte
5 = Raw data (0..30000) 2 Byte
0
1
Bit0..3
decimal places for subchannel 1
1
Bit4..7
decimal places for subchannel 2
2
Bit0..3
decimal places for subchannel 3
2
Bit4..7
decimal places for subchannel 4
3
decimal places for subchannel 5, 6
4
decimal places for subchannel 7,8
5
decimal places for subchannel 9,10
6
decimal places for subchannel 11,12
7
decimal places for subchannel 13,14
8
decimal places for subchannel 15,16
9
decimal places for subchannel 17,18
10
decimal places for subchannel 19,20
11
decimal places for subchannel 21,22
12
decimal places for subchannel 23,24
13
decimal places for subchannel 25,26
14
decimal places for subchannel 27,28
15
decimal places for subchannel 29,30
16
decimal places for subchannel 31,32
17
Bit7... 0
Enable Bit 8... 15 control bit in control word
18
Bit7... 0
Enable Bit 0... 7 control bit in control word