AED
CONNECTING INTERFACES AND I/OS
38
7.4.2
Connecting the diagnostic bus
GND/0 V of U
V
S3
KL3
TB/RB
TA/RA
Fig. 7.13
Connecting the diagnostic bus
Also see section 7.1.4 on page 30 for more information on the diagnostic bus.
7.4.3
Connecting digital inputs/outputs
The AED9301B has 2 inputs and 6 outputs. Define the functions using the commands
IMD, LIV and OMD.
KL1
KL2
0 V
OUT1
OUT2
OUT4
OUT3
External load
0 V of U
V
IN1
IN2
+10
…
30 V
Separate power supply
Fig. 7.14
Connecting digital inputs/outputs
Inputs IN1/2 are electrically isolated from the external supply voltage U
V
and from the
amplifier. The 0V connection of both inputs is not connected to 0 V of the supply voltage
U
V
. If the input circuit is also supplied via U
V
, you must connect 0V of the inputs and 0V
of U
V
. If you do not need the inputs, do not assign them.