35
AED
CONNECTING INTERFACES AND I/OS
7.3.2
Connecting the diagnostic bus
KL1
KL2
GND
TB/RB
TA/RA
Fig. 7.10
Connecting the diagnostic bus
Also see section 7.1.4 on page 30 for more information on the diagnostic bus.
7.3.3
Connecting digital inputs/outputs
The AED9201B has 2 inputs and 6 outputs. Define the functions using the commands
IMD, LIV and OMD.
Inputs IN1/2 are electrically isolated from the external supply voltage U
V
and from the
amplifier. The 0V connection of both inputs is not connected to 0 V of the supply voltage
U
V
. If the input circuit is also supplied via U
V
, you must connect 0V of the inputs and 0V
of U
V
. If you do not need the inputs, do not assign them.