HB-100/140/160Z1
Temperature Control Unit
Operation
O8285-EN 2017-12
73
Remote mode settings
(additional equipment ZD, ZC,
ZP, ZO)
Operation and monitoring of the temperature control unit can take
place via the serial interface.
Fig. 40: Set address, protocol
The following settings must be made in order to communicate with
an external controller:
1.
Display the menu page
Setting \ Remote operation
.
2.
Set parameter
Address
to the desired value.
3.
Set parameter
Protocol
to the desired value.
NOTE!
A set address may only exist once in a network.
Network settings (Additional
equipment ZO)
Fig. 41: Network settings
The following settings must be made in order to communicate with
an external controller through the network (OPC UA):
1.
Select the menu page
Setting \ Remote \ TCP/IP
Configuration
.
2.
Make network settings.
If a DHCP server is available, the
DHCP
parameter must be set to
"yes". Then an IP address will be automatically procured from the
DHCP server.
If no DHCP server is available, the settings with the
IP,Standard
gateway
and
Subnet mask
parameters must be set manually.
NOTICE!
The settings will be applied on leaving the menu.
Any active connections will be automatically
disconnected.
Irrespective of which protocol is set (apart from
Protocol 19, data can be written and read) the
OPC UA protocol is activated. In this case, data
can only be read.