Assembly Instructions M8095-EN
M8095-EN 2020-09
10/13
Product group Treat-5 and Clean-5
1.
Main switch off, remove the plug from the mains and empty
the unit.
2.
Loosen the screws in the front panel and hinge it down.
3.
Proceed as follows in order to remove the GIF-51 (A 4):
Remove all connectors.
Remove screws on the sides of the board.
Unplug the printed circuit board level measuring (A 10)
Fig. 14: Front panel
4.
Change unit board GIF-51 (A 4):
Remove the printed circuit board level measuring (A 10) and
plug in on the new GIF-51.
Install new GIF-51 and fasten it with screw.
Connect plug connections.
Connection main pump cable (X 62/X 64):
Voltage 200
–220 V
Slot X 62 (triangle)
Voltage 380
–480 V
Slot X 64 (star)
Fig. 15: Voltage selection GIF-51
5.
Voltage selection at X 15 with bridge plug (O/ID T21608):
Verify mains voltage (
specification on the nameplate)
Place bridge according (
Fig. 15)
ATTENTION!
Danger if wrongly connected
Wrong voltage selection or wrong connections can
damage the unit
Therefore:
– Thoroughly check connections and voltage
selection
6.
Close and secure the front panel.
X 15