Hayward Super Star Clear C2000 Скачать руководство пользователя страница 1

PUMP SELECTION AND LOCATION

To power your filter, select a continuous duty pump designed
for swimming pool or spa service.

It is important to first determine where your pump and filter will
be located.  If above the water line, a self-priming pump must
be used. Self-priming pumps (

such as Hayward Super Pump

®

,

Super II™ or Max-Flo™) have the ability to lift water from a
lower level and prime automatically.

Select a pump with an average output range suitable for the filter's
capacity.  Other considerations are operation of hydrotherapy
fittings, automatic cleaners, etc.  Your dealer will help you
select the proper size pump for your system.

FILTER LOCATION

Since plumbing fittings offer a resistance to water flow,
position the filter as close to the swimming pool as practical.
Keep the number of fittings to a minimum.  Select a
well-drained area, one that will not flood when it rains.

The filter should be placed on a 

level concrete slab, very

firm ground, or equivalent, as recommended by your pool
dealer.  Allow a top clearance for cartridge removal of 18

(457 mm) for C2000, C3000 and C4000, 22

(559 mm) for

C5000. Be sure filter, pump, drain and pressure gauge are
accessible for convenient operation.

Position filter so the tank can drain by gravity.

If practical, place pump and filter in the shade to shield it
from continuous, direct heat from the sun.

PLUMBING

Use 1-1/2

or 2

piping.  Connections are 1-1/2

socket

(solvent weld) or 2

male slip.  We suggest unions be

provided for easy servicing.

Refer to the diagram for typical installation.  Ball valves are
recommended where needed.  While all systems vary, the
main consideration is to provide the desired control of
water flow from the pool to the pump and filter and back to
the pool.  When the filter is located below the water level,
provide valves to prevent back flow of water to the filter
during cleaning and routine servicing.

Connect the pool suction plumbing between the skimmer,
pool outlet, etc., and the pump.

Install the pool return plumbing.

If pressure gauge is not installed, apply Teflon tape to the
gauge threads, and 

carefully screw the gauge into the

gauge adapter assembly.

A filter drain plug is furnished with each filter and is all that
is needed for complete filter draining.  A manual air vent
valve is furnished to aid in bleeding off unwanted air when
starting the filter.  The auto air relief provides air removal
during operation.

All electrical connections should be made in accordance
with local codes.

Check for joint leaks before operating.

Refer to pump instruction booklet for pump information.

NOTE: ANSI/NSPI-4 Article V, standard for above-ground and
on-ground pools, advises that components such as the
filtration system, pumps and heater be positioned so as to
prevent their being used as a means of access to the pool by
young children.

BEFORE STARTING THE FILTER

Superchlorinate the pool water by adding unstabilized granular
or liquid chlorine.  Stabilized forms of chlorine are recommended
for normal daily use after the initial clean up of the water.
Follow chemical manufacturer’s recommendations for
superchlorination and daily use.

ISC2000-98

1.

2.

3.

4.

1.

2.

3.

4.

5.

6.

7.

8.

9.

OWNER’S GUIDE

MODELS C2000, C3000, C4000, C5000

Hayward Super Star-Clear filters are high performance swimming pool filters with filtration ratings to 9000
gallons (34 KL) per hour. Manufactured from durable, corrosion-proof materials, they are designed for
continuous or intermittent operation, for installation above or below the pool water line, for fresh or salt water
swimming pools or spas. Star-Clear filters utilize multiple reusable, reinforced polyester filter cartridge
elements to provide a high degree of water clarity and long filter cycles with absolute minimum care.

31-3/4

(807 mm)

36-1/2

(927 mm)

42-1/2

(1080 mm)

48-1/2

(1232 mm)

C2000

C3000

C4000

C5000

Содержание Super Star Clear C2000

Страница 1: ...back flow of water to the filter during cleaning and routine servicing Connect the pool suction plumbing between the skimmer pool outlet etc and the pump Install the pool return plumbing If pressure gauge is not installed apply Teflon tape to the gauge threads and carefully screw the gauge into the gauge adapter assembly A filter drain plug is furnished with each filter and is all that is needed f...

Страница 2: ... O ring and carefully place over Filter Body lip Clean Filter Head flange sealing surface and place over Tank O ring pressing down firmly and evenly to seat the Filter Head in place Replace Clamp Assembly Make sure clamp is located and centered properly over the filter flange If Clamp is tight tap Clamp with rubber mallet or block of wood to help seat it Insert threaded stud through retainer and s...

Страница 3: ...e effective against algae though algaecides should be used in conjunction with and not as a substitute for regular chlorination or superchlorination Maintaining a chlorine level of at least 1 0 ppm in the pool water at all times is the most effective way to prevent algae growth in swimming pools PLEASE REALIZE Pure clear swimming pool water is a combination of two factors adequate filtration and p...

Страница 4: ...X2400Z3A SX200Z5 DEX2400BT DEX3600BT DEX4800BT DEX6000BT DEX2400J DEX2400J4 DEX2400JS DEX2400J3 DEX2400JN DEX2400K CX2000DA CX3000DA CX5000DA CX3000F1B CX3000FB DEX360M CX800Z4 CX3000Z3 CX4000Z3 CX5000Z3 CX3000J CX470XRE CX570XRE CX870XRE CX1260RE CX3000C DEX2400A1T SPX1022C SX360Z1 DEX360FB SX200Z4 SX240F SX200R DESCRIPTION Pressure Gauge Relief Valve Gauge Adapter Assy O Ring for Relief Valve St...

Страница 5: ...o screws at the bottom of the manifold so that the filter and the manifold can be drained thoroughly ISC3000INS 99 IMPORTANT For winterizing in addition to removing the drain plug at the bottom of the filter please also make sure to remove the two screws at the bottom of the manifold so that the filter and the manifold can be drained thoroughly ...

Отзывы: