background image

OWNER’S Manual

PRINTED IN CANADA

10/2009

Содержание Summit Heat Pump

Страница 1: ...OWNER S Manual PRINTED IN CANADA 10 2009 ...

Страница 2: ......

Страница 3: ... 10 Electrical Connections 11 Wiring Diagram 12 Service Analyzer Control 13 Operation 14 Caring for your Pool Heater 15 Initial Startup 16 Meaning of Display Codes 17 Troubleshooting 18 Requesting Assistance or Service 20 Maintenance 21 Winterizing 21 Hayward Heat Pump Pool Heater Limited Warranty 22 International Warranty 23 Notes 24 Warranty Card Registration 25 Table of contents OWNER S MANUAL ...

Страница 4: ...s gas or oil fired the SUMMIT pool heat pump has a lower heating capacity on a BTU hr basis Therefore it needs to operate for a longer time to accomplish the desired results Occasionally it may be necessary to run the heat pump for up to 24 hours per day However this should not be of concern to the owner because the heater is designed to operate continuously What s more despite continuous operatio...

Страница 5: ...er Please also record the purchase date of your device and your dealer s name address and telephone number Model Number ____________________________________________________ Serial Number_____________________________________________________ Purchase Date ____________________________________________________ Dealer Name ______________________________________________________ Dealer Address ___________...

Страница 6: ...he CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in material damage particularly to the product up to the destruction of part or all of the product WARNING The WARNING sign denotes a hazard It calls attention to a procedure practice or the like which if not correctly performed or adhered t...

Страница 7: ...Always install the machine outdoors unless otherwise approved by the manufacturer while respecting the minimal clearances needed for proper operation and heating CAUTION Proper pool chemistry is vital to the life of your heater Pay particular attention to the total alkalinity and TDS It is highly recommended that you have your pool chemistry checked often by an independent pool store 5 OWNER S MAN...

Страница 8: ...the very least all around your heat pump The use of 90 degree bends and short radius elbows in the water piping should be kept to a minimum Mount the unit on a sturdy base preferably a concrete slab or a set of blocks The base should be completely isolated from the building foundation wall to prevent the possibility of sound or vibration transmission into the building The size of the base should n...

Страница 9: ...an withstand high pressure The installation of a heat pump bypass is not necessary unless the water flow exceeds 75 GPM Note Certain installations have valves which isolate the heat pump from the water circuit If the heat exchanger is deprived of water circulation for several days high chlorine gas could cause excessive corrosion If the disconnect switch is turned off be sure that the pool water i...

Страница 10: ...pment All electric and metal components must then be bonded to each other and then to the copper rod CAUTION 1 A 1 3 lb check valve must be installed between the heater and any automatic chlorine distribution system if used 2 Any kind of automatic chlorine distribution system must be installed after or downstream of the heat pump 3 The filter must be placed before or upstream from the heat pump 4 ...

Страница 11: ...Bonding and Plumbing diagram Fig 2 Fig 3 Heat Pump Chemical feeder 9 OWNER S MANUAL ...

Страница 12: ... SPA mode can be controlled with an external switch to heat up to 80 degrees Internal mode Use the P_S mode on the main menu External mode Open contact POOL mode Closed contact SPA mode Control using a switch To control the board using an external switch follow these steps Turn on the heat pump Set POOL mode to OFF Set SPA mode to the desired temperature Access the setup menu Select mode E externa...

Страница 13: ...e knock out located on the left or the right side of the base and then insert it in the control box The electrical diagram is located on the lid of the control box as well as in this manual WARNING Ground L1 L2 Fig 5 Power requirements 240 V 1 PH 60 Hz Look at the name plate loca ted on the heat pump to know the required amperage Please refer to your local electrical code for additional wiring req...

Страница 14: ...sensor High pressure switch Closed OK Opened high pressure Low pressure switch Closed OK Opened low pressure Flow switch Closed flow Opened no flow Orange 240 Vac or Red 208 Vac 24 Vac compressor contactor CAP 24 Vac transformer Ground Remote switch Pool opened Spa closed P S WS DS HP HP LP LP FLO FLO HGD H C FAN FAN COMPRESSOR COMPRESSOR 24 VAC 208 230 Vac 60 Hz 1 Phase CAP 24 Vac OWNER S MANUAL ...

Страница 15: ...in Fahrenheit degrees 13 OWNER S MANUAL Temperature and parameter display Celsius or Fahrenheit mode Access to parameters To raise the desired temperature or to change parameters To lower the desired temperature or to change parameters Heating mode Compressor or fan running Heating mode ...

Страница 16: ...program press the SET key until you see P_S and by press ing one of the arrow keys you can switch to POL or SPA Once the heating mode has been programmed it will be displayed for five seconds and will then return to the actual pool water temperature The lights on the right side of the display indicate the chosen heating mode To display the temperature in F or in C Press the SET key until you see F...

Страница 17: ...Caring for your Pool Heater How to protect your pool heater 15 OWNER S MANUAL ...

Страница 18: ... water temperature you desire The fan will immediately start The compressor will start after a 3 to 4 minute delay When the compressor is running the HEATING CHAUFFAGE indicator located on the right see Service Analyzer Control p 13 should be lit At initial startup it is normal for the unit to run 24 hours a day It is also normal to see water dripping from the holes at the base of the unit This is...

Страница 19: ...ackwash filter and or heater The unit will show HP3 after 3 HP faults This will stop your heater for protection Po Water temperature probe connected to WS on the electronic board may be disconnected If it is not the probe may be open or defective Pc Water temperature probe is short circuited or may be defective FLo Possible causes The filter is in backwash position The filter pump is stopped The f...

Страница 20: ... is not Pool pump is not running Filter is dirty restricting the water flow Turn the pool pump on Backwash and clean filter The heater is displaying flo and it will not start Heat pump control set to OFF Desired water temperature is reached Main breaker is tripped Raise temperature set point above 60 F 15 C Unit will automatically restart when the water temperature goes below the set point Reset ma...

Страница 21: ...ensation It is normal to see condensation dripping under the heater To check if the water really is a leak you must stop the heater and leave the pool pump running for over 5 hours If water is still coming out of your heater after this period then call your dealer for service There is water around the unit Heat loss is too much for the heater cover your pool as often as you can Evaporator restrict...

Страница 22: ...all your dealer It may save you the cost of a service call If you still need help follow the instruc tions below Service can be obtained by calling one of these phone numbers CANADA 1 888 238 7665 USA 1 908 355 7995 When asking for help please provide a detailed description of the problem your heater s complete model and serial number and the purchase date see p 3 This information will help us res...

Страница 23: ...must turn the breaker off The unit must be drained of all its water You will need to disconnect the IN and OUT water connections Then the unit must be tilted or blown out with air until all water is out The next step is to reconnect your IN and OUT water connections that will have previously been drained It is recommended to cover the heat pump to prevent snow from getting inside A protective wint...

Страница 24: ...d the normal intended use of the unit or acts of God This warranty is void if the product is repaired or altered in any way by any persons or agencies other than those authorized by HAYWARD and is in lieu of all other warranties expressed or implied written or oral There are no implied warranties of merchantability or fitness for a particular purpose that apply to this product This warranty applie...

Страница 25: ...acture date and applies only if the product is installed according to the HAYWARD specifications This warranty does not include the repair of damage due to negligence accident freezing installation in corrosive environ ments or atmospheres conditions beyond the normal intended use of the unit or acts of God There are no implied warranties of merchantability or fitness for a particular purpose that...

Страница 26: ...24 Notes OWNER S MANUAL ...

Страница 27: ......

Страница 28: ......

Отзывы: