USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 12 of 15
VL Series Pump
ISVL1285 Rev B
8.2.
Replacement Parts Listing
Ref. No.
Description
Model VL2280
Model VL2285
1
Strainer Cover Assembly
SPX8100LDS
SPX8100LDS
2
Strainer Cover O-Ring
SPX8100S
SPX8100S
3
Strainer Basket
SPX8100M
SPX8100M
4
Male Adapter Kit
SPX8100UNBPAK
SPX8100UNBPAK
5
Male Adapter O-ring
SPX8100UNO
SPX8100UNO
6
Pump Housing
SPX8100AA
SPX8100AA
7
Drain Plug Assembly
SPX1700FG
SPX1700FG
8
Housing Fix Screw Kit
SX180KKIT
SX180KKIT
9
Base
VLX2280G
VLX2280G
10
Shroud Fix Screw Kit
SPX0714Z2
SPX0714Z2
11
Seal Plate O-Ring
GMX600F
GMX600F
12
Diffuser Gasket
SPX8100R
SPX8100R
13
Diffuser
SPX8100B
SPX8100B
14
Impeller
VLX1280TC
VLX1280TC
15
Shaft Seal Assembly
SPX1600Z2
SPX1600Z2
16
Seal Plate
SPX8100E
SPX8100E
17
Shroud Screw Kit
SPX2700Z3PAK4
SPX2700Z3PAK4
18
Rear Shroud
VLX2280AM2
VLX2280AM2
19
Switch
LTBCYXSW
LTBCYXSW
20
Motor Mounting Screw
SPX8100Z1
SPX8100Z1
21
Front Shroud
VLX2280AM1
VLX2280AM1
22
Motor
VLX2280Z1C
VLX2285Z1C
23
Slinger
SPX1500Q6
SPX1500Q6
24
Housing Screw Kit
6060XZ1
6060XZ1
25
25' Cord Set
SPX1550WA5CH
SPX1550WA5CH
*
Items 17 & 18 not shown in figure 8.1-1
9.
Troubleshooting
9.1.
General Problems
•
Motor Will NOT Start:
1.
Check for and correct any improper or loose wiring connections; open switches or relays; tripped circuit
breakers, or blown fuses.
2.
With the power disconnected, manually check the rotation of the motor shaft for free movement and lack of
obstruction. Correct if necessary.
•
Motor Shuts OFF:
1.
Check for low voltage or power drop at the motor (frequently caused by undersized wiring). Contact a
qualified professional to verify the electrical connections.