VGB Compliant ANSI/APSP/ICC-16 2017 LISTED

Certificate of conformity available at 

https://www.1paramount.com/downloads/manuals/mdxr3/MDXR3CertificateOfConformity.pdf

MDX-R3 and SDX2 must be installed in accordance with Paramount’s 
written instruction manual, and in conformity with applicable Federal, 
State, Local and Swimming pool industry building and safety codes.

Any modification that increases the flow rate of the circulation system shall require reevaluation 
of the cover/grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly 
(SOFA) is not exceeded.

When installing and using this equipment, basic safety precautions
shall always be followed, including the following: 

IMPORTANT SAFETY INSTRUCTIONS.

TO INSTALLERS: READ, UNDERSTAND, 

AND FOLLOW ALL INSTRUCTIONS AND 

WARNINGS. 

Give these instructions to the facility owner to keep for future reference. Follow all codes and 
regulations that apply to the design, installation and use of suction outlet fittings. 

NOTICE

 

WARNING

SAVE THESE INSTRUCTIONS

MDX-R3 FOR VINYL POOLS

OWNER’S MANUAL AND INSTALLATION GUIDE

EUROPE

SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

Paramount products are designed by Paramount in Phoenix, Arizona, United States of America 

004-027-8822-00           REV05   ECN_2006   PUB072921   ©2021 Hayward Industries, Inc.

Содержание Paramount MDX-R3

Страница 1: ...ll require reevaluation of the cover grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly SOFA is not exceeded When installing and using this equipment basic safety precautions shall always be followed including the following IMPORTANT SAFETY INSTRUCTIONS TO INSTALLERS READ UNDERSTAND AND FOLLOW ALL INSTRUCTIONS AND WARNINGS Give these instructions to the facility o...

Страница 2: ...re notice and keep the pool or spa closed until an appropriate ANSI APSP ICC 16 2017 certified drain cover is properly installed Missing broken or cracked SOFA component shall be replaced before bathers are allowed to use the pool Loose cover grates shall be reattached before bathers are allowed to use the pool DANGER DANGER DEATH or SERIOUS INJURY will result from hair entanglement or limb entrap...

Страница 3: ...ailure to do so can result in hair or body entrapment which can cause death or serious injury If in doubt about the rating of your system consult a qualified pool or spa professional Use only the supplied stainless steel screws with the drain cover Screws put into the frame anywhere except in the original screw holes will not hold and will allow the drain cover to come off the main drain causing a...

Страница 4: ... is installed with or without water See parts breakdown at end of this manual for specific component service life notations Any SOFA component that is severely faded chalking or brittle when flexed shall be replaced even if it has not reached its indicated service life If the sump mud ring or any screw receptacle is stripped cracked or broken that component must be replaced Any SOFA component held...

Страница 5: ...LLOW the section of the included installation instructions explaining how to calculate the suction system flow ratings and that of the installed pumping system WARNING In the event of one suction outlet being completely blocked the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump s for the specific suction system MDX R3 VGB COMPLIANT DEBRI...

Страница 6: ...3mm PORT 75mm 75mm SDX2 2ND SUCTION OUTLET TO PUMP SKIMMER BYPASS 75mm TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SUCTION PLUMBING PER LOCAL CODE ENLARGED SUCTION ELEMENT IF NOT USING HYDROSTAT PLUG 63mm PORT 75mm SDX2 2ND SUCTION OUTLET TO PUMP SKIMMER BYPASS TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SUCTION PLUMBING PER LOCAL CODE ENLARGED SUCTION...

Страница 7: ...ODE TO PUMP SDX2 2ND SUCTION OUTLET MV FUSE DECK SIDE SDX2 2ND SUCTION OUTLET EQUAL SIZE 75 mm MINIMUM ENLARGED SUCTION ELEMENT IF NOT USING HYDROSTAT PLUG 63mm PORT TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SUCTION PLUMBING PER LOCAL CODE TO PUMP TO PUMP TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SUCTION PLUMBING PER LOCAL CODE SDX2 2ND SUCTION OUT...

Страница 8: ...icular to inside wall or end wall of pool Whichever pool base is used the drain sump must be encased in concrete as shown to anchor it in place 2 Position the REQUIRED SDX2 High Flow Safety Drain on a sidewall of the pool below water level if pool will be winterized place it high enough to reach from the deck Option The SDX2 High Flow Safety Drain may be positioned on the floor a MINIMUM of one 1 ...

Страница 9: ...talled shall not protrude more than 2 51mm from the finish surface of the pool in which the SOFA is installed NOTICE 1 Remove 4 pressure plug 2 SOFA components and fastener receptacles shall be clean and free of debris and obstruction during installation of cover grate fasteners 3 Install funnel assembly 3 onto leveling ring 5 and secure with 4 four security screws 2 with screw driver security T25...

Страница 10: ...e to the non ribbed side of the two notched gaskets 2 Align the gaskets with the alignment tabs and screw holes then press the gaskets onto the Bulkhead Fitting and the Bulkhead Support 3 SOFA components and fastener receptacles shall be clean and free of debris and obstruction during installation of cover grate fasteners 4 After installing the Vinyl Liner align the SDX2 Vinyl Fiberglass Support w...

Страница 11: ...w line to achieve airlock Repeat vacuum out canister For winterizing canister visit www 1Paramount com and click on winterization instructions WITHOUT CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2 1 Remove grate from wall drain and install a 13 blow through plug and blow line to achieve airlock 2 If 3rd suction line is installed remove grate install a 1...

Страница 12: ... Enlarged Suction Element 005 272 0841 00 Screw Pack Vinyl 19 pcs 14 004 172 2231 XX SDX2 High Flow Safety Drain 15 005 252 0811 00 SDX2 Screw Pack For Vinyl 16 005 252 2098 XX SDX2 Cover w Screws Vinyl Fiberglass 17 Screw 12 14 X 1 B 12 pcs 18 005 252 2061 00 SDX2 Support Vinyl Fiberglass 19 005 252 0072 00 SDX2 Gasket Vinyl Fiberglass 2 pk 20 005 252 2035 00 SDX2 Bulkhead Vinyl Fiberglass 2 1 2 ...

Отзывы: