29
4
5
6
7
2T1 4T2
N
L3
L2
L1
6T3
A2
14N0
1L1 3L2 5L3
A1
13N0
2
1
3
8
L3
L2
L1
R S
T N
= = = =
1 2
=
=
6.3 Heating priority wiring for three phases pump
Power supply
400V 3N
/ 50 Hz
Three phases pump
Dry contact 16 A max
Terminals 1 and 2 deliver a potential-free dry contact,
230V
/ 50 Hz, no polarity.
Wire terminals 1 and 2 as indicated in the diagram
above, to activate the operation of the filtration pump
in 2-minute cycles each hour if the temperature of the
pool is lower than the set point.
Never connect the power supply of the filtration
pump directly to terminals 1 and 2.