background image

WARNING

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

PO BOX 2000  •  HOUGHTON, IOWA 52631 • USA

PHONE: 319-469-4141  •  FAX: 319-469-4402

WEB: www.haweyesteel.com  •  E-mail: [email protected]

ISH77ASSY

REV. 1.6

PRINTED IN U.S.A.

77ASSY - 77 Heater Assembly 

For Models MK32 & MJ31

INSTRUCTIONS

WARRANTY INFORMATION

1.  INSTALLATION MUST BE MADE AND MAINTAINED IN STRICT ACCORDANCE WITH 

NATIONAL/LOCAL PLUMBING AND NATIONAL/LOCAL ELECTRICAL CODES (CSA IN 

CANADA).  INSTALLATION MUST BE MADE BY A QUALIFIED ELECTRICIAN.  THE 

APPLICABLE PROVISIONS OF THE ABOVE MENTIONED CODES TAKE PRECEDENT.   

IMPROPER ELECTRICAL INSTALLATION AND MAINTENANCE MAY RESULT IN SERIOUS 

INJURY OR DEATH FOR PERSONNEL OR LIVESTOCK.

2.  EACH ELECTRICAL UNIT MUST BE WIRED THROUGH A FUSED SWITCH BOX AND 

FUSED ACCORDING TO AMPS REQUIRED FOR EACH SPECIFIED ELECTRICAL UNIT.  

CANADIAN ELECTRICAL CODE--PART 1 REQUIRES LIVESTOCK WATERERS INSTALLED 

IN FEEDLOTS IN OPEN FEEDING AREAS TO BE GROUNDED BY A SEPARATE STRANDED 

COPPER GROUNDING CONDUCTOR OF AT LEAST NO. 6 AWG TERMINATING AT A POINT 

WHERE THE BRANCH CIRCUIT RECEIVES ITS SUPPLY.

3. THIS UNIT MUST BE GROUNDED TO A COPPER GROUND ROD 5/8" (1.6CM) DIAMETER 

BURIED AT LEAST 10 FEET (3.1 METERS) IN UNDISTURBED SOIL.

WHEN ORDERING PARTS

(1) Show MODEL NUMBER and NAME: Example - 77 Space Heater

HOW TO ORDER PARTS

Repair parts may be ordered from your dealer.

1.  Remove the access door by turning the 2-

1/4

 Turn SS Studs (push in and twist counter-

clockwise).  Discontinue electrical service to any existing electric unit.

2.  Inside the waterer on the underneath side of the trough, locate the center bolt that is 

welded to the bottom of the trough and protruding downwardly.

3.  Place bracket on this center bolt and tighten with one of the brass nuts.

4.  Place the heater on the bolt that is welded to the bottom of the bracket.  Attach the 

heater to the bracket by placing the pre-drilled hole in the middle of heater on the brack-

et bolt.  MAKE SURE THE HEATING ELEMENT OF THE HEATER IS FACING UP AND 

THAT THE POWER CORD IS ON THE LEFT SIDE AS THE HEATER IS MOUNTED. Turn 

the electric unit at an angle as much as possible(and still allow the access door to be 

replaced) so that you see and access the control knob.  Tighten heater to the bottom of 

the bracket using the second brass nut.

5.  Plug in power cord.

Part Number Description

Qty.

77

Space Heater

1

MK315

Junction Box Stand-off Bracket

1

OF58

5/16

-18

 X 9/16 X 7/32

 Hex Machine Nut, Brass

2

ISH77ASSY

Instruction Sheet

1

COPYRIGHT © 2018

ALL RIGHTS RESERVED

!

!

NOTE: MH30 takes two 77ASSY - 77 Assembly Heaters.  MJ31, MK32 require only one.