Series 5000 EPRV (8 - 12”) Installation, Operation and Maintenance Guide - Oct-2021
1
N OT E : I N F O R M AT I O N R E Q U I R E D F O R S U CC E S S F U L
I N S TA L L AT I O N
C AU T I O N : I N F O R M AT I O N I F N OT F O L LOW E D M AY
R E S U LT I N DA M AG E O R I N S TA L L AT I O N FA I L U R E
WA R N I N G : I N F O R M AT I O N I F N OT F O L LOW E D M AY
R E S U LT I N I N J U RY O R D E AT H
PA RT A :
I N S TA L L I N G S E R I E S 5000 E P RV
TOOLS
»
Pair of 3/4 Box and/or Socket Wrench for weight
attachment.
»
Pair of box and/or socket wrench for flange bolting
(torque wrench preferred). See below for sizes:
WRENCH SIZES
CONNECTION
SIZE
REC. TORQUE
†
8” API
3/4
14 FT-LB
10” ANSI 150#
1-5/16
48 FT-LB
12” ANSI 150#
68 FT-LB
†
Values above based on achieving a 4-psi bubble tight
seal using full-face chloroprene gasket on smooth and
clean surfaces. Installing with fastener torques higher than
suggested may reduce long-term sealing performance,
and user does so at own risk.
PARTS REQUIRED
»
1× Single arm Series 5000 EPRV (8, 10 or 12”)
»
1× Base Gasket (*)
»
1× Bolt Kit sized for connection (*)
* Match to EPRV connection size.
1
Place tank gasket and EPRV on the Flange and align
holes.
I N STA L L AT I O N , O P E R AT I O N A N D M A I N T E N A N C E G U I D E
S E R I E S 5000 E P RV (8 - 12”)
This document contains the recommended procedures for installing, operating and maintaining the Series 5000 EPRV in 8, 10, 12 Sizes. Read and understand this document prior to
installation, operation or maintenance of the EPRV.
2
Secure EPRV in place with bolts and nuts supplied
in the bolt kit. Use washers on the EPRV side of the
bolted connection. Install hand-tight, then torque to
recommended value using sequence shown in Section
C4.
3
Remove nut and top washer from weight hanger
bolt and set weights over weight hanger bolt. The set
pressure of the EPRV with no weights installed is 1 ozsi
and increases with the addition of weight plates.
4
Replace weight hanger nut and washer and tighten
to 68 ft-lb.
WEIGHT PART NUMBER REFERENCE
8 NPS
10 NPS
12 NPS
1.0 ozsi 220.310.040
225.310.051
225.312.051
2.0 ozsi 220.310.050
225.310.052
225.312.052
STANDARD INSTALLATION COMPLETE.
A2 (OPTIONAL) TRANSPORT LOCK
The transport lock can be installed on the 8” EPRV to
prevent damage to the device while the tank is being
transported in the vertical or horizontal position. The
transport lock holds the EPRV in a slightly open position.
This restricts entry of dust and contaminants into the
tank and prevents the internal pressure of the tank from
exceeding allowable limits during transport and if the
lock is accidentally left in place when the tank is placed in
service.
N OT E : T H E T R A N S P O RT LO C K I S O N LY AVA I L A B L E O N
T H E 8” A P I E R P V.
PARTS REQUIRED
»
1× Installed 8” EPRV
»
1× EPRV Transport Lock Kit
1
Remove the cotter pin, washers and clevis pin from the
transport lock kit.
2
Set the forked end of the transport lock arm over the
lock attachment point on the EPRV base and replace
the cotter pin, washer and clevis pin.
3
The transport lock can be left in the lowered position
until it is required. To prepare the EPRV for transport
proceed to section B1.