Assembly Instructions
AI 306 / Issue M - 11/08
Assembly Instructions for cable gland:
501/423 Exd IIC/Exe II/ExtD
123 Industrial General Purpose
Gland Type: 501/423 Exd IIC/Exe II/ExtD
Baseefa06ATEX0056X II 2 GD A21 IP66
IECEx BAS06.0013X
CEPEL No: CEPEL-EX-060/2001X
CSA No: 1015065 (LR 78713-7)
Gland Type: 123 Industrial
Certified to Hawke Approved Drawings Only
Certification Details
1. Backnut
1.1 Compression
Spigot
1.2 Seal
2. Middle
Nut
2.1 Compression
Spigot
2.2 Seal
3. Entry
Cable Preparation
Gland Preparation
A
Allow sufficient length of cable,
II
, to suit equipment.
If required, fit shroud.
Pass cable through cable gland as shown above.
Note :
If the equipment has a threaded entry, it may be
advisable to screw the cable gland into the equipment to
prevent twisting of the cable after Step B & C.
B
Unless already screwed into the equipment hold
the entry
in position with a spanner/wrench to
prevent rotation and tighten the middle nut
using a wrench/spanner until resistance is felt
between the seal and cable. Then turn the middle
nut through a further half to one full turn to
complete the inner seal.
C
Hold the middle nut
in position with a spanner/
wrench to prevent rotation and tighten the backnut
using a wrench/spanner untill resistance is felt between
the seal and cable, then turn the middle nut through a
further half to one full turn to complete the outer seal.
Locate the shroud over the cable gland, if applicable.
To ease wiring inside the equipment it may be beneficial
to strip the outer sheath of the cable, as shown above.
IMPORTANT:
Support the cable to prevent twisting.
II
Shroud Option
5mm minimum
recommended
II
3
2
1
3
2
1
3
2
1