7
Operation
DANGER
Risk to life due to electric shock
Touching live components, directly or indirectly, will cause injuries or death.
Do not use the charger outdoors. The protection class of the charger is IP 20.
Keep the charger socket and the charger itself clean and dry at all times.
Comply with the relevant electrical safety regulations.
Observe the manufacturer’s operating instructions
■
The product is activated via the machine/system controls of the manufacturer.
■
Information on this can be found in the operating instructions of the machine/system manufac-
turer.
Optimum operation of the battery pack
■
Use only the charger that is supplied (Zivan NG3 for 3 kW or Zivan NG5 for 5 kW).
■
Do not perform any cleaning work on the device whilst it is in operation.
■
Do not use any multi-way sockets or distributor sockets.
■
Do not perform any cleaning work on the device whilst it is being charged.
■
If the battery pack is going to be out of service for longer than two months, it should be
charged to about 60% before being placed in storage.
■
Do not interrupt the charging process at a charge status less than 30%.
✓
The higher-level machine meets the requirements set out in Directive 2006/42/EC.
✓
The product is connected and wired correctly.
✓
The labels and markings on the higher-level machine and the product are easy to see and read.
✓
The STO function was tested in accordance with
✓
Use only the charger that is supplied (Zivan NG3 for 3 kW or Zivan NG5 for 5 kW).
Charging procedure with
charger NG 3 or NG 5
DAMAGE
The charging socket acts as the interface between the charger and the battery pack.
The following steps are necessary for charging the battery pack (battery):
Use of a charger that is not in conformity is prohibited (this might damage the battery).
The charger and cables have been checked for wear and approved as safe to use.
■
A 230 V socket rated 16 A is required for the 3 kW charger.
■
A 400 V three-phase socket rated 16 A is required for the 5 kW charger.
1. Fully swing down the black locking bar.
2. Fully swing up the grey cover of the charging socket.
3. Plug in the charger:
✓
The battery pack must lie on a re-resistant base (for external charging).
✓
The charger must not be covered whilst it is being charged.
✓
The charger must not be exposed to direct sunlight whilst it is being charged.
✓
The charging cable must not be taut.
✓
The ambient temperature is above 0°C. (Charging cannot be performed at temperatures below 0°C)
HAWE Hydraulik SE
B 6130 - 02-2022 - 1.0en
23/39