5.2 Electrical connection
DAMAGE
Damage from kinked or crushed power cables
Kinked or crushed power cables may cause wires to sever and cables to catch re.
►
Never kink or crush cables.
WARNING
Electrical and magnetic elds
Electrical and magnetic elds impair the functionality of cardiac pacemakers and implanted defibrilla-
tors.
►
People with pacemakers or implanted defibrillators must maintain a sufcient distance from
magnets.
►
Advise people with pacemakers or implanted defibrillators against approaching magnets.
►
Cordon off the area around the drive system and afx suitable warning signs to the barriers.
WARNING
Danger due to signal interference at check valve
The electromagnetically actuated check valve of the hydraulic locking unit can be subject to interference
from electrical, magnetic and electromagnetic elds in the surrounding environment. Signals cannot be
transmitted correctly as a result. This can lead to hazardous situations, and danger to life.
►
Lay power and signal cables so that they do not affect the check valve.
►
Use only cables designed for the specic application type (xed, exible or highly exible;
outdoor).
►
Follow the cable manufacturer's instructions for selecting the cable type.
►
Include all metal components of the ride in the equipotential bonding plan.