DAMAGE
Damage from connecting soiled components
Connecting soiled components may cause system failure and irreparable damage.
Clean the workspace before connecting the hydraulic system.
Clean hydraulic components before connecting the hydraulic system.
Only use hydraulic uid of sufcient grade.
Add components which are not in the scope of delivery (e.g. bolts, screws and sleeves for attachment,
hydraulic uid). Use ltered hydraulic uid.
1. Space required for assembly, installation and commissioning: 500 x 500 x 500 mm (WxHxD).
2. Place the hydraulic power pack in position in the higher-level machine.
3. Ensure all the fastening bores and hydraulic connections align correctly. Installation space:
400 x 150 x 200 mm (W x H x D)
4. Fasten the hydraulic power pack via the 2 x M6 fastening bores on the equipment rack.
5. Connect the hydraulics:
Exact connection designation and dimensions in D 6025
Version Q: via the 2 x M10x1 threaded connections on the equipment rack
Version H: via the 1 x M14x1.5 threaded connection on the equipment rack
6. After a week of operating time at the latest, check the ttings.
5.2 Electrical connection
DANGER
Risk of fatal injury from electric shock
Touching live components directly or indirectly causes injury or death.
Only trained specialist personnel are permitted to replace or connect electronic components.
Obey all applicable electrical safety rules.
Only connect electric lines to the hydraulic system while the system is de-energized.
WARNING
Electrical and magnetic elds
Electrical and magnetic elds impair the functionality of cardiac pacemakers and implanted defibrilla-
tors.
People with pacemakers or implanted defibrillators must maintain a sufcient distance from
magnets.
Advise people with pacemakers or implanted defibrillators against approaching magnets.
Cordon off the area around the drive system and afx suitable warning signs to the barriers.
16/34
B 6025 - 12-2021 - 1.1en
HAWE Hydraulik SE