A
B
C
D
E
F
G
H
I
69
4000327280
E09.16
USA / GB
HA120PX
D
- Operation instructions
6.2 -
HYDRAULIC OIL
External environmental conditions can reduce performance of the machine if the hydraulic oil
temperature does not reach its optimum range.
It is recommended to use the hydraulic oil according to weather condition. Refer to the table
below.
N.B.-:-It is recommended to replace low temperature oil as the ambient temperature r 15°C
(59°F). It is not advisable to mix oils of different brands or types.
6.3 -
PREHEATING OPERATION
When power is switched ON, the electric pre-heating indicator ( 1 ) (at the ground control box)
and / or ( 51 )
(on the platform control box) flashes, the motor is in automatic pre-
heating. Upon the extinction of this light (just seconds) at the ground display, starting of the
machine is possible.
Environmental conditions
SAE Viscosity grade
Ambient temperature between - 15°C (5°F) and + 40°C (+ 104°F)
HV 46
Ambient temperature between - 35°C (- 31°F) and + 35°C (+ 95°F)
HV 32
Ambient temperature between 0°C (+ 32°F) and + 45°C (+ 113°F)
HV 68
Содержание HA120PX
Страница 1: ...Operator s manual HA120PX 4000327280 E09 16 USA GB Operator s manual HA120PX ...
Страница 2: ...2 4000327280 E09 16 USA GB HA120PX ...
Страница 6: ...6 Operator s manual ...
Страница 28: ...28 4000327280 E09 16 USA GB HA120PX B Familiarization 3 2 GROUND CONTROL BOX 3 2 1 Layout General view ...
Страница 30: ...30 4000327280 E09 16 USA GB HA120PX B Familiarization 3 3 PLATFORM CONTROL BOX 3 3 1 Layout General view ...
Страница 38: ...38 4000327280 E09 16 USA GB HA120PX B Familiarization Notes ...
Страница 70: ...70 4000327280 E09 16 USA GB HA120PX D Operation instructions Notes ...
Страница 71: ...A B C D E F G H I 71 4000327280 E09 16 USA GB HA120PX E General Specifications Notes General Specifications ...
Страница 84: ...84 4000327280 E09 16 USA GB HA120PX E General Specifications Notes ...
Страница 90: ...90 4000327280 E09 16 USA GB HA120PX F Maintenance Notes ...