2    Safety 

 

 

 

2

 

Safety 

Only the persons authorized by the operator may carry out tasks on 
the discharging power pack. 
 
The installer must be a trained and qualified electrician and read the 
operating instructions in full. 
The operator must read the operating instructions in full. 
 
When working on the discharging power pack, switch off the voltage 

supply and secure against inadvertent switching on. 
 

 

 

Hazards caused by manipulated or faulty discharging power 
pack 

Unauthorized modifications, moisture or damage to the discharging 
power pack may result in electric shocks or fire hazards due to 
sparking. 

•  For reasons of safety, never open or modify the discharging 

power pack. 

•  In the event of visible damage or suspected electrical defects, 

take the discharging power pack out of operation immediately 
and secure against inadvertent reuse. 

•  Protect the discharging power pack from moisture. 
•  Never carry out any unauthorized repairs to the discharging 

power pack. 

•  Always switch off the discharging power pack after use. 
•  Do not keep any inflammable materials in the vicinity of the 

discharging power pack or its components. 

 

 

 

Damage to device and risk of fire 

Short circuits can occur as a result of soiling in the high-voltage (HV) 

connection point. This can lead to faults with the discharging power 
pack and cause a fire. 
•  The high-voltage connections and plugs must be clean, dry and 

free of grease. 

•  Use blind plugs to protect the unused HV connection points 

against environmental influences. Ensure that the blind plugs are 
clean, dry and free of grease. 

 

 

 

 

Содержание 01.7912.005

Страница 1: ...Static Line Operating instructions Discharging power pack EN 8 SLC MT Ident number 01 7913 055 100 V 01 7913 005 200 V 01 7912 005 230 V Keep for future use GB...

Страница 2: ......

Страница 3: ...Product overview 8 4 Install 9 5 Operate 13 5 1 Normal operation 13 5 2 Cyclic operation 13 6 Troubleshooting 14 6 1 Replacing fuse 15 6 2 Flow chart 16 7 Accessories spare parts 17 8 Technical data...

Страница 4: ...eviated HV in these operating instructions e g HV terminal The illustrations in this document are a simplified representation of the product They render only the technical facts and provide support fo...

Страница 5: ...ose of with household garbage Caution danger spot warning 1 2 Symbols on the discharging power pack WARNING High voltage ATTENTION Only plug in unplug the ionizing unit at the HV terminal when the dis...

Страница 6: ...In the event of visible damage or suspected electrical defects take the discharging power pack out of operation immediately and secure against inadvertent reuse Protect the discharging power pack from...

Страница 7: ...tmospheres The discharging power pack is intended exclusively for the supply of alternating high voltage to HAUG ionizing units with X 2000 connector In combination with an ionizing unit electrostatic...

Страница 8: ...switch is lit green if the discharging power pack is switched on B Indicator light C Fuse holder with fuse Replacing fuse refer page 15 D 2 x HV connection E Signalling socket with jumper plug F Eart...

Страница 9: ...us overloading of the discharging power pack may result in failures Never exceed the permissible connected length Never install the discharging power pack on a surface generating or radiating heat Nev...

Страница 10: ...fect its function We recommend attaching the discharging power pack with the HV connections facing downwards protection against moisture oil and dirt 4 Make sure that the discharging power pack is swi...

Страница 11: ...witched on spark overs will occur at the HV connection This may result in defects in the discharging power pack Switch off discharging power pack before plugging in unplugging ionizing unit 7 Connect...

Страница 12: ...e Pin 2 0 V Pin 3 not used Pin 4 not used Pin 5 Clock switch connection Pin 6 Clock switch connection PE Shield Ground signal ground NOTE The discharging power pack only supplies voltage if the signal...

Страница 13: ...eration fails the indicator light turns off In order to correct the malfunction proceed with troubleshooting the error Refer page 14 5 2 Cyclic operation The signal line K6 is connected to the K6 sign...

Страница 14: ...is provided on the back of the envelope Fault Cause Troubleshooting Mains switch does not illuminate Mains failure Check mains fuse Defective fuse in discharging power pack Check fuse in discharging...

Страница 15: ...es Never bridge the fuse The unit type and the rated voltage are indicated on the nameplate 1 Disconnect the discharging power pack 2 Determine and rectify the reason for the fuse failure 3 Use a scre...

Страница 16: ...g socket Switch on the discharging power pack yes Switch off discharging power pack and connecting a ionizing unit Switch on the discharging power pack This ionizing unit has a fault Short circuit Ion...

Страница 17: ...e authorized local sales agent of Mettler Toledo Article Order number Point electrode 11107765 Optional second electrode 11107762 U Electrode universal 11107764 U Electrode small 11140161 Ionizing kit...

Страница 18: ...rt circuit current Ik 5 mA Square wave signal Pulse width Tp To Cycle in 40 Cycle out 1 Amplitude 10 V 20 Frequency 1 kHz 20 Polarity Positive 8 2 Supply voltage Unit type Rated value Frequency range...

Страница 19: ...e mean seal level to 2000 m Temperature Rated application range 5 to 45 C Limit range for storage and transport 15 to 60 C Relative humidity Rated application range A RF B C Air pressure Rated applica...

Страница 20: ...data 20 8 4 Housing Protection type IP 20 Protection class I Excess power category II Degree of pollution 2 Mains connection via the IEC power cable Dimensions Height 245 mm Width 128 mm Depth 125 mm...

Страница 21: ...ct the signalling line from the discharging power pack 5 Remove the discharging power pack from the production process 9 1 Storing Always store our products in a dry and cool place 9 2 Disposing Never...

Страница 22: ......

Страница 23: ......

Страница 24: ...EN 8 SLC MT v09gb docx V09 22 01 2019 D 0273 GB made by...

Отзывы: