6 Troubleshooting
14
6
Troubleshooting
Electric shock hazard!
The discharging power pack is operated electrically and generates a
high electric voltage. In the event of any faults, there is a risk of an
electric shock.
• Faults may only be eliminated by a trained and qualified
electrician.
NOTE:
If the error cannot be removed in this way, return the discharging
power pack and ionizing unit for checking to HAUG GmbH & Co. KG
(the address is provided on the back of the envelope).
Fault
Cause
Troubleshooting
Mains
switch
does not
illuminate.
Mains failure
Check mains fuse
Defective fuse in
discharging power
pack.
Check fuse in discharging power
pack.
Ionisation
not
available
No HV
Check connections in
discharging power pack.
Electrically
conductive
deposits on
ionizing unit.
Clean ionizing unit
Discharging power
pack is damaged.
Shut the discharging power pack
down immediately and secure
against switching on.
Signalling
lamp does
not
illuminate
during
operation.
The ionizing system
has a fault.
Perform work steps according to
the following flow chart. Refer
page 16..