2L41C, 2M41, 2M41Z
Operation and use
HATZ
45
Operator’s Manual
NOTICE
i
▪
If the engine stops again immediately after starting, or stops
independently during operation, this is an indication that a
monitoring element of the automatic shutoff has activated.
▪
Remedy the fault before making further starting attempts
(see chapter
▪
The automatic shutoff is
no
protection against low oil level.
This means that the oil level must be checked every 8 - 15
operating hours despite the automatic shutoff. (see section
7.8 Check the oil level, page 49
Procedure when faults occur
Step
Activity
1
Check the indicators (5-7).
After the engine comes to a standstill, the fault will continue to
be displayed by the indicator for approx. another 2 minutes.
2
Then the electrical equipment switches off automatically.
3
Set the starting key to position "0".
4
Turn the starting key back to position "I".
The fault display lights up again.
Remedy the fault before making further starting attempts (see
chapter
The indicator then goes out at the next start.
7.6
Switching off the engine
Safety notes
CAUTION
Danger of injury from unauthorized access.
There is a danger of injury if unauthorized persons handle the
machine.
▪
Protect the crankhandle and starting key against unautho-
rized access upon breaks in operation or after completing
work.
CAUTION
Danger of engine damage.
▪
Never stop the engine on the decompression lever.