DATASHEET

Hatteland Technology AS | www.hattelandtechnology.com | Enterprise no: NO974533146

1/6

The remote controller enables the control of Series 1 G2, Series X G1, Series X G2, MVD Series and selected HM CMD / RMD monitors 

by providing instant keypad functionality over RS-485/422 bus through the well implemented SCOM Protocol by Hatteland Technology 

AS. A single press on the remote controller will trigger the same physical press on all connected/configured units with the

synchronized reaction of corresponding button presses. The remote controller provides several functions through 3 physical buttons 

for user interaction. Remote Control is powered and driven by first monitor unit (which has to be connected to external power cable/

source. It is not required to turn the monitor unit on for the Remote Control to control/operate other monitor units that may be in 

the same chain).

External Remote Controller for Monitors

Manufacturer: 

Hatteland Technology AS

Product:

 

External Remote Controller for Monitors

Typenumber: 

HD REM SX1-A1

Last Revised:

 

16 Sep 2022

Revision#: 

21

Description:

ACCESSORY

• Connector

1 x 6-pin Terminal Block 3.81, non-isolated

• Mounting

Includes mounting bracket with 2 x PanHead M3x6mm.

(Tightening Torque 0.8 Nm) and 2 x Thumb Fastening screws for console 

mounting.

• Physical Dimensions

W:125.00 [4.92"] x H:37.50 [1.48"] x D:72.30 [2.83"] mm [inch]

 

• Weight

123g

• Connectivity

- Shipped with 1 x 6-pin Terminal Block 3.81 loose connector (Art: 1828388)

- Connect Remote Control to first display unit, other units in connection chain

  will receive same commands. 

- See page 2 for Physical Wire Connections.

• User Manual

- This datasheet. Detailed usage: SCOM Technical Manual can be used with

  command-set regarding User Controls:

Series 1 G2 models: 

  https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-12.htm

 

Series X G1 models: 

  https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-4.htm

Series X G2 models: 

  https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-6.htm

Multi Vision Display MVD models: 

  

https://www.hattelandtechnology.com/hubfs/pdfget/inb100018-8.htm

• 

Test and certificate

Hatteland Technology standard, (tested / type approved by the

following classification societies):

IEC 60945 4th (EN 60945:2002), IACS E10,

EU RO MR

 - Mutual Recognition, 

ClassNK

 - Nippon Kaiji Kyokai

Specifications: