background image

Safety Stands

USER’S MANUAL

Publication 5502-002 Rev 2.0

45-0207 (Model 630B)

  Cuvette Safety Stand

47-0208

 

Extended Capacity Flatpack Safety Stand

47-0203

 

AgilePulse MAX Cuvette Safety Stand

47-0209

 

AgilePulse MAX Extended Capacity Flatpack Safety Stand

47-0610N

 

AgilePulse PLUS Extended Capacity Flatpack Safety Stand

Содержание BTX 45-0207

Страница 1: ...45 0207 Model 630B Cuvette Safety Stand 47 0208 Extended Capacity Flatpack Safety Stand 47 0203 AgilePulse MAX Cuvette Safety Stand 47 0209 AgilePulse MAX Extended Capacity Flatpack Safety Stand 47 0610N AgilePulse PLUS Extended Capacity Flatpack Safety Stand ...

Страница 2: ...any reference to electroporation and electrofusion We extract the pertinent experimental conditions and yields from these papers to help us in our efforts to help you In addition to tracking publications we are available to you for support at any time for advice in experimental design product recommendations troubleshooting and any other relevant technical advice We thank you again for your invest...

Страница 3: ...y Stand 5502 002 Rev 2 0 www btxonline com Table of Contents SUBJECT PAGE Warranty Information 2 General Safety Information 3 Introduction 4 Operation Getting Started 5 Specifications 6 Ordering Information 7 ...

Страница 4: ...ises within the warranty period promptly contact BTX 84 October Hill Road Holliston Massachusetts USA 01746 1388 using our toll free number 1 800 272 2775 US Only or 508 893 8999 E mail support hbiosci com Goods will not be accepted for return unless an RMA Returned Materials Authorization number has been issued by our customer service department The customer is responsible for shipping charges Pl...

Страница 5: ...roduct Read all labels on product to ensure proper usage High Voltage Risk These BTX Safety Stands are designed to connect to a high voltage power supply adjustable to 3 000 V High voltage power supplies present a serious risk of personal injury if not used in accordance with design and or use specifications if used in applications on products for which they are not intended or designed or if they...

Страница 6: ...0208 47 0203 47 0209 47 0610N Compatible BTX Generators ECM 399 ECM 630 ECM 830 ECM 2001 Gemini X2 When used with F F adapters Item 45 0088 Sold separately ECM 399 ECM 630 ECM 830 ECM 2001 Gemini X2 When used with included F F adapters Item 45 0088 AgilePulse MAX ECM 2001 AgilePulse MAX ECM 2001 AgilePulse PLUS Compatible BTX Cuvettes All 1 mm 2 mm and 4 mm gap BTX cuvettes All 1 mm 2 mm and 4 mm ...

Страница 7: ...t the distance between the contacts using the black roller Note the adjustment will remain the same after the first time do not readjust the roller with every cuvette However check contact periodically to ensure good current flow Close the safety stand shield 4 Switch on the BTX electroporator Check that all instrument settings and connections are correct Deliver electroporation pulse protocol by ...

Страница 8: ...ge Temperature 10 to 70 C Operating Temperature 5 to 40 C Intended Use Indoor Use Only Relative Humidity 20 to 80 Maximum Altitude 2 000 m 6 562 ft Pollution Degree II Insulation Category CAT I Physical Characteristics Overall Dimensions 45 0207 47 0203 L x W x D 12 7 x 10 2 x 17 8 cm 5 x 4 x 7 in Overall Dimensions 47 0208 47 0209 L x W x D 12 7 x 10 2 x 19 0 cm 5 x 4 x 7 5 in Weight 1 kg 2 3 lb ...

Страница 9: ...sfer pipettes Pkg of 10 45 0125 BTX Cuvettes Plus 2 mm gap 400 µl Sterile Blue cap individually wrapped with transfer pipettes Pkg of 50 45 0141 BTX Cuvettes Plus 2 mm gap 90 µl Sterile Blue cap bulk wrapped in packages of 100 cuvettes per pkg Pkg of100x24 45 0135 BTX Cuvettes Plus 4 mm gap 800 µl Sterile Yellow cap individually wrapped with transfer pipettes Pkg of 10 45 0125 BTX Cuvettes Plus 4 ...

Страница 10: ...US Canadian Customers phone 508 893 8999 fax 508 429 5732 e mail support hbiosci com website www btxonline com International Customers To locate a distributor near you please visit our website at www btxonline com ...