HARTING mCon 3000 Скачать руководство пользователя страница 13

20

HARTING Electric GmbH

21

Management Software Ha-VIS mCon Series / Edition 2.4

System Settings

User Manual Ha-VIS mCon Switch Management Software

Management

Function

Description

Default/Mgmt-VLAN 

ID:

Change of the Management VLAN

Range of value:

 

1 ... 4094

 

Default value:

 

1

HTTP Port

Sets the http port for the web interface.

Range of value:

 

1 ... 65535

 

Default value:

 

80

Multifunction Button

Enable or disable the Multifunction Button on the switch

Range of value:

 Enable

 / 

Disable 

Default value:

 Enable

8.2  Port Settings

This section informs you on how to change the settings for the switch’s Ethernet ports. The ports 
can be individually enabled (up) or disabled (down). The data transfer rate and mode of data flow 
can be determined as well as the compatibility parameters for the network. Note that there are 
two tabbed sections (

Basic Settings 

and 

Port Control

) where these settings can be made.

8.2.1  Basic Settings

Figure 8-3 

Basic Settings tab

In this tabbed section, the administrative state of individual ports can be specified. Each port row 
has the following columns. 

Function

Description

Select/Port

Select the port that you would like to change by clicking on the 
checkbox here.

Admin State

Select the desired state of the port. A port can be either enabled (up) 
or disabled (down). 

Range of value:

  UP

 / 

DOWN 

Default value:

 

UP

Link Status

Displays the port status. A green circle in this column indicates that a 
device is connected to this port. A red circle indicates that no device 
is connected.

Function

Description

Save IP Address 

Persistent

Check this box to save the IP address permanently. You will no 
longer be able to connect to the switch using the old IP address. 
Using your web browser, connect to the switch using the new IP 
address.

Subnet Mask

Specify the subnet mask for the network. If the subnet mask is 
entered manually. This value is assigned automatically if you have 
a DHCP server.

Default Gateway

Specify the default gateway for the switch

Be sure to remember to click on the 

Apply

 button to save your changes. Then click on the 

Save 

Configuration 

button which appears at the bottom of the window to save the settings permanently.

The lower section of the 

General Settings 

window lists additional status information. This includes: 

the switch MAC address, the default VLAN identifier, the configuration save status, the remote 
save status, the configuration restore status and the HTTP port number.

8.1.2  Switch Management 

This chapter describes the configuration of the various system and session related features, 

like web session and service functionalities

.

Figure 8-2 

Switch Management window

Web Session

Function

Description

Web Session Timeout

Sets the timeout for each web session. Without any action on the web 
interface, the session will be terminated after the timeout timer expires.

Range of value:

 

1 ... 3600 seconds

 

Default value:

 

600

Maximum Number of 

Web Sessions

Sets the maximum number of parallel web sessions.

Range of value:

 

1 ... 10

 

Default value:

 

2

Содержание mCon 3000

Страница 1: ...HARTING Ha VIS Management Software mCon 3000 Next Generation User Manual Web Interface...

Страница 2: ...H Editor HARTING All rights reserved including those of the translation No part of this manual may be reproduced in any form print photocopy microfilm or any other process processed duplicated or dist...

Страница 3: ...oduction to the Web Browser Interface 13 6 1 The menus 13 6 2 Accept and saving changes with the Save Configuration button 14 6 3 User rights 16 7 Overview 17 8 System Settings 19 8 1 General Settings...

Страница 4: ...he Overview section 17 Figure 8 1 General Settings window 19 Figure 8 2 Switch Management window 20 Figure 8 3 Basic Settings tab 21 Figure 8 4 Port Control tab 22 Figure 8 5 User Management tab 23 Fi...

Страница 5: ...e 17 4 Port Mirroring section 75 Figure 17 5 Switch History event list 76 Figure 17 6 MAC Address Table 78 Figure 17 7 Light Beacon functionality 79 Figure 17 8 Ping functionality 79 Figure 18 1 Inter...

Страница 6: ...ons 1 2 and 3 or using the Command Line Interface CLI via Telnet or ssh This software guide for the Ha VIS mCon family of switches contains information required to operate the switch management softwa...

Страница 7: ...s displayed or specified 3 3 Additional information Mounting instructions for this switch can be found in the Installation Notes included in the delivery The Installation Notes also provide valuable h...

Страница 8: ...you can also install a TFTP server program on this PC in the event that you need to update the switch firmware or export respectively import a configuration file 4 1 Switch access and configuration T...

Страница 9: ...ia the Multifunction Button MFB the customer is able to set some specific parameters of the switch without accessing it via Web or SNMP This chapter describes how to use the MFB and the Service Mode F...

Страница 10: ...any of the various second level menu choices Figure 6 2 The menu tree 6 1 3 The active window Most of the screen is taken up with the active window in which settings and statistics for the switch are...

Страница 11: ...n Device Location Displays the location of the device as defined by the user in the General Settings section Device Description MAC address of the switch Part No Displays the HARTING part number of th...

Страница 12: ...e standard timeouts and waiting periods are reduced to a minimum It is recommended to set this option to enable if Option 82 is used IP Address Specify the IP address of the switch IP addresses are as...

Страница 13: ...n indicates that a device is connected to this port A red circle indicates that no device is connected Function Description Save IP Address Persistent Check this box to save the IP address permanently...

Страница 14: ...rticipating interfaces to automatically determine the best possible transmission parameters The auto negotiation function can either be activated Enable or deactivated Disable If Enable is selected th...

Страница 15: ...n allows you to specify the basic SNMP settings This switch software supports SNMP versions 1 2c and 3 You may also enable both versions simultaneously Figure 8 7 SNMP section 8 3 2 Change Password Fi...

Страница 16: ...atus can be of the types read only or read write Function Description Enable Check this box to launch the SNMP agent and allow access to the switch via SNMP version 1 2c Range of value Enable Disable...

Страница 17: ...The Refresh button allows you to refresh your view of neighbouring chassis IDs port IDs and IP addresses The following information are shown Local Port Local port where the information was learned Nei...

Страница 18: ...summer and winter time This should be taken into account when evaluating log files or alarm generated e mails in which the time is logged 8 6 2 Precision Time Protocol PTP PTP in accordance with stand...

Страница 19: ...provides its time to the other slaves End to End transparent clock The switch forwards the PTP messages which are exchanged between the masters and the slaves and adds the processing time in the swit...

Страница 20: ...t a new firmware file just click on the browse button to search for a file on a remote system and select it via the standard windows interface After the selection of the file click to Import to start...

Отзывы: