3 Block MEASURED VARIABLES
Device Functions Proline Promag 55
20
Hauser
3.3
Group
SPECIAL UNITS
3.3.1
Function group ARBITRARY UNIT
MEASURED
VARIABLES
A
⇒
MEASURING VALUES
AAA
⇓
SYSTEM UNITS
ACA
⇓
SPECIAL UNITS
AEA
⇒
ARBITRARY UNIT
060
Function description
MEASURED VARIABLES
➞
SPECIAL UNITS
➞
ARBITRARY UNIT
Use this function group to define an arbitrary unit for the flow rate variable.
TEXT ARBITRARY
VOLUME
(0602)
Use this function to enter a text for the selectable volume unit / volume flow unit. You
define only the text, the unit of time is provided from a choice of options (s, min, h, day).
User input:
xxxxxxx (max. 4 characters)
Valid characters are A–Z, 0–9, +, –, decimal point, white space or underscore
Factory setting:
"_ _ _ _" (No text)
Example:
If your text entry is "GLAS", this text string appears on the display complete with the unit
of time, e.g. "GLAS/min":
GLAS = Volume (text input)
GLAS / min = Volume flow as shown (on the display)
FACTOR ARBITRARY
VOLUME
(0603)
Use this function to define a quantity factor (without time) for the selectable unit. The
volume unit on which this factor is based is one liter.
User input:
7-digit floating-point number
Factory setting:
1
Reference quantity:
Liter
Example:
The volume of a glass is 0.5 l
→
2 glasses = 1 liter
User input: 2
Содержание Proline Promag 55
Страница 2: ...Device Functions Proline Promag 55 2 Endress Hauser ...
Страница 5: ...Device Functions Proline Promag 55 Contents Endress Hauser 5 ...
Страница 164: ...14 Index Device Functions Proline Promag 55 164 Endress Hauser ...
Страница 166: ...www endress com worldwide BA120D 06 en 10 09 71104957 FM SGML6 0 ...