Device Functions Proline Promag 55
10 Block SPECIAL FUNCTION
Hauser
135
10.1.5
Function group COATING E2
SPECIAL FUNCTION
H
⇒
ADV. DIAGNOSTICS
HEA
⇒
CONFIGURATION
750
⇓
ACQUISITION
751
⇓
CONFIG. COATING
752
⇓
COATING E1
753
⇓
COATING E2
754
Function description
SPECIAL FUNCTION
➞
ADV. DIAGNOSTICS
➞
COATING E2
REFERENCE VALUE
(7540)
Use this function to view the reference value for the decay time constant at measuring
electrode 2.
User interface:
5-digit floating-point number, including unit in milliseconds
ACTUAL VALUE
(7541)
Use this function to view the actual measured decay time constant at measuring
electrode 2.
User interface:
5-digit floating-point number, including unit in milliseconds
MINIMUM VALUE
(7542)
Use this function to view the lowest measured value for the decay time constant at
measuring electrode 2, since the last reset or deletion of the stored values.
User interface:
5-digit floating-point number, including unit in milliseconds
MAXIMUM VALUE
(7543)
Use this function to view the highest measured value for the decay time constant at
measuring electrode 2, since the last reset or deletion of the stored values.
User interface:
5-digit floating-point number, including unit in milliseconds
HISTORY
(7544)
Use this function to view the last 10 measured values for the decay time constant at
measuring electrode 2.
User interface:
5-digit floating-point number, including unit in milliseconds
ACTUAL DEVIATION
(7545)
Use this function to view the deviation between the actual (last measured) value for the
decay time constant at measuring electrode 2 and the reference values selected in the
SELECT REFERENCE CONDITION function (7502).
User interface:
5-digit floating-point number, including unit in milliseconds
WARNING LEVEL
(7546)
!
Note!
This function is not available unless the ON setting was selected in the WARNING
MODE function (7503).
In this function, the user can enter a maximum permitted deviation (limit value) from the
reference status for the decay time constant. If this limit value is overshot or undershot, a
system error message (categorized as a notice message) is output. To do this, the
measuring system compares the actual deviation (see Function ACTUAL DEVIATION,
7535) to the value entered here.
User input:
1 to 10000 ms
Factory setting:
100 ms
Содержание Proline Promag 55
Страница 2: ...Device Functions Proline Promag 55 2 Endress Hauser ...
Страница 5: ...Device Functions Proline Promag 55 Contents Endress Hauser 5 ...
Страница 164: ...14 Index Device Functions Proline Promag 55 164 Endress Hauser ...
Страница 166: ...www endress com worldwide BA120D 06 en 10 09 71104957 FM SGML6 0 ...